background image

GigaVUE TA Series

Hardware Installation Guide

GigaVUE-OS 5.7.00

GigaVUE-TA40

GigaVUE-TA1 and GigaVUE-TA10

GigaVUE-TA100

GigaVUE-TA200

Содержание GigaVUE TA Series

Страница 1: ...GigaVUE TA Series Hardware Installation Guide GigaVUE OS 5 7 00 GigaVUE TA40 GigaVUE TA1 and GigaVUE TA10 GigaVUE TA100 GigaVUE TA200...

Страница 2: ...any form or by any means without Gigamon s written permission TRADEMARK ATTRIBUTIONS Copyright 2019 Gigamon Inc All rights reserved Gigamon and the Gigamon logo are trademarks of Gigamon in the United...

Страница 3: ...A100 Chassis 18 Chassis Cooling 20 Power LEDs 21 System LED 21 Port Status LEDs 21 Global Fan LED 22 Individual Fan LEDs 22 Individual Power LEDs 22 GigaVUE TA100 Notes and Rules 22 Dual BIOS Images 2...

Страница 4: ...p 43 Getting Unpacked Racked Installed and Connected 43 Chapter 3 Rack Mounting GigaVUE TA Series 45 Unpacking the GigaVUE Traffic Aggregator 45 Rack Mounting the GigaVUE TA Series 46 Chapter 4 Basic...

Страница 5: ...24 Position Fiber Cable for Use with SR10 Transceivers 88 A GigaVUE TA Series Specifications 89 Physical Dimensions and Weight 90 Power Requirements 90 Fan Tray Specification for GigaVUE TA100 and TA...

Страница 6: ...ibility 103 Class B Voltage Accessibility 103 Equipment Grounding Systems 103 Communication Equipment Grounding 103 Bonding of Battery Return BR Input Terminals 103 Connections 103 Input AC DC Voltage...

Страница 7: ...sis on page 12 Introducing the GigaVUE TA40 Chassis on page 16 Introducing the GigaVUE TA100 Chassis on page 18 Introducing the GigaVUE TA100 CXP Chassis on page 24 Introducing the GigaVUE TA200 Chass...

Страница 8: ...te the traffic from multiple low utilization links before sending the traffic to the GigaVUE H Series or G Series nodes that form your Gigamon Visibility Platform IMPORTANT The GigaVUE TA Series suppo...

Страница 9: ...t 48 1Gb 10Gb ports 4 40Gb ports Optional patch or breakout panel support Cluster with H Series nodes GigaVUE TA40 1RU Footprint 32 40Gb ports Optional patch or breakout panel support Cluster with H S...

Страница 10: ...r the following features and benefits High density visibility for 1Gb 10Gb 40Gb and 100Gb Low profile 1RU 2RU for GigaVUE TA200 design offers easy deployment at the top of rack or end of row in data c...

Страница 11: ...variety of GigaVUE TA Series node events helping you keep tabs on system status in real time Scalable Port Density The GigaVUE TA10 can have either twenty four 24 or forty eight 48 1Gb 10Gb ports ena...

Страница 12: ...ists of a 1RU rack mountable 19 wide chassis with management network and tool ports at the front and power connections at the rear Figure 1 1 shows the ports at the front of the GigaVUE TA10 chassis R...

Страница 13: ...raffic Aggregator also includes four 40Gb ports q1 q4 suitable for use as tool ports for aggregated output to a matching 40Gb port on a GigaVUE H Series node You can also configure card modes that let...

Страница 14: ...ort For details about the supported transceivers and cable type refer to the GigaVUE OS Compatibility and Interoperability Matrix Refer to Port Licensing on page 63 for license information to expand t...

Страница 15: ...formation on a GigaVUE TA10 node show chassis show environment type psu show environment type psu psu detail all psu id NOTE To increase the i2c stability in a GigaVUE TA10 node the frequency of updat...

Страница 16: ...2 suitable for use as tool ports for aggregated output to a matching 40Gb port on a GigaVUE H Series node You can also configure card modes that let a 40Gb port operate as four logical 10Gb ports Once...

Страница 17: ...Ports q1 q32 GigaVUE TA40 includes 32 40Gb ports q1 q32 The 40Gb ports can be used as a 40Gb ingress port or as a high speed tool port for aggregated output to a matching 40Gb port on a GigaVUE H Ser...

Страница 18: ...e running software version 4 6 01 or higher The GigaVUE TA100 node in a cluster environment must be running software version 4 8 or higher Figure 1 3 The GigaVUE TA100 Chassis Front View 100Gb QSFP28...

Страница 19: ...o x4 appended to their port ID for example 1 1 c2x1 For details refer to Configure the Port Mode on page 40 Once a 40Gb port has been configured to operate as four 10Gb ports cable it to an optical pa...

Страница 20: ...current exhaust CPU and switch CPU temperatures as well as the intake temperature config show environment Card 1 TA100 C32 Intake temperature 40 C Exhaust temperature 45 C CPU temperature 32 C Switch...

Страница 21: ...e system LED on the front of the chassis is as follows Off indicates no power Blinking GREEN indicates the node is booting or the system is in diagnostic mode Solid GREEN indicates normal operation So...

Страница 22: ...e GigaVUE OS Compatibility and Interoperability Matrix Network Tool Hybrid or Stack Link Port The 100Gb 40Gb ports on GigaVUE TA100 can be used as network tool hybrid or stack link ports Subports crea...

Страница 23: ...on If a BIOS upgrade is needed for enhancements in future releases the BIOS can be manually upgraded from the CLI using the coreboot install command Stack Links at 100Gb The GigaVUE TA100 can connect...

Страница 24: ...wered versions of the GigaVUE TA100 Refer to Connecting 48V DC Power Supplies on page 54 Battery Caution A disposable non rechargeable Real Time Clock RTC Lithium metal coin cell battery is in the Gig...

Страница 25: ...nnections to the GigaVUE CLI using Telnet SSH Green LED shows link status amber LED shows activity LEDs PWR SYSTEM and FAN USB Port GigaVUE TA100 CXP Front View Console and Mgmt Ports CXP Ports The 10...

Страница 26: ...Gb port has been configured to operate as four 10Gb ports cable it to an optical patch panel or breakout panel such as PNL M341 which takes a 40Gb QSFP input from the GigaVUE TA100 CXP and splits it t...

Страница 27: ...d switch CPU temperatures as well as the intake temperature config show environment Card 1 TACX C28 Intake temperature 31 C Exhaust temperature 39 C CPU temperature 30 C Switch_CPU temperature 52 C Th...

Страница 28: ...system LED on the front of the chassis is as follows Solid GREEN indicates normal operation Blinking GREEN indicates the node is booting or the system is in diagnostic mode Solid RED indicates a crit...

Страница 29: ...Ds on the rear of the chassis are as follows GREEN indicates the PSU is operating normally Off indicates the PSU is not operational GigaVUE TA100 CXP Notes and Rules Keep in mind the following notes a...

Страница 30: ...s 2ndflashboot Secondary flash boot notification If a BIOS upgrade is needed for enhancements in future releases the BIOS can be manually upgraded from the CLI using the coreboot install command Softw...

Страница 31: ...l ports at the front and power connections and fans at the rear Figure 1 7 shows the ports at the front of the GigaVUE TA200 chassis Refer to Table 1 7 for a description of each of the ports Figure 1...

Страница 32: ...s activity This port is also used in a cluster configuration to manage cluster traffic LEDs PWR SYS and FAN USB Port GigaVUE TA200 Front View Console and Mgmt Ports 100Gb 40Gb Ports The GigaVUE TA200...

Страница 33: ...panel or breakout panel such as PNL M341 which takes input from the GigaVUE TA200 and splits it to four independent 10Gb 25Gb output ports Refer to Breakout Panels on page 41 Ports c11 c22 or c11x1 c1...

Страница 34: ...rt or critical temperature conditions Refer to Table 1 8 for the temperatures at which the warning alert and critical traps are sent and any additional action that occurs at a threshold Table 1 8 Comp...

Страница 35: ...SFP Power 7 8 dBm SFP Power 9 10 dBm SFP Temperature C 19 75 The output of the following CLI command displays the fan speed in RPM the normal operational speed is approximately 5000 RPM the maximum sp...

Страница 36: ...cates the system has failed Port Status LEDs For each port there are four 4 port status LEDs on the front of the chassis At 40Gb and 100Gb speeds only the first LED operates as follows AMBER indicates...

Страница 37: ...em booted using asterisks config show version GigaVUE TA200 Notes Transceivers For details about the supported transceiver cable type and connectivity specifications refer to GigaVUE OS Compatibility...

Страница 38: ...follows 2ndflashboot Secondary flash boot notification Air Flow Direction The air flow direction is from the front of the GigaVUE TA200 chassis to the rear The rear mounted fans pull air from the fro...

Страница 39: ...0 Then refer to Breakout Panels on page 41 Configuring the Card Mode on GigaVUE TA10 The following card modes are available for the GigaVUE TA10 48x default Four 40Gb ports q1 q4 and 48 10Gb ports x1...

Страница 40: ...e Port Mode The port breakout modes are as follows 4x10G Specifies the 4x10G port breakout mode This mode applies to GigaVUE TA40 GigaVUE TA100 and GigaVUE TA200 nodes and to QSFP28 ports on GigaVUE T...

Страница 41: ...ts on a GigaVUE TA40 is 96 24 x 4 The 100Gb QSFP28 ports 1 1 c1 to 1 1 c10 and 1 1 c23 to 1 1 c32 on the GigaVUE TA200 can be broken out into four 25Gb ports called subports The subports will all have...

Страница 42: ...42 GigaVUE TA Series Hardware Installation Guide...

Страница 43: ...tarted 1 Step 1 Rack Mount GigaVUE Traffic Aggregation node Refer to Rack Mounting the GigaVUE TA Series on page 46 Step 2 Connect Power Serial console and Mgmt Ports Refer to Basic Connections and Co...

Страница 44: ...44 GigaVUE TA Series Hardware Installation Guide...

Страница 45: ...o delivered it Remove the protective shipping covers and screws Save the protective shipping covers and replace the screws in the holes on the system so that they are easily saved in case you need to...

Страница 46: ...rovided for the rack before installing the chassis Unsecured racks can tip over Install boxes in the rack from the bottom up with the heaviest boxes at the bottom Ensure adequate ventilation to the sy...

Страница 47: ...rews As shown in Figure 3 1 the rack ears can be attached for a front mount or rear mount installation Select the installation that best fits the needs For example one position may provide better clea...

Страница 48: ...gregator with Rail Mounting for Four Post Racks To mount the GigaVUE Traffic Aggregation node in a four post rack 1 Attach the orange rack ears to the front of the unit using the supplied screws Figur...

Страница 49: ...rails can be adjusted to fit the dimensions of the rack by sliding over the rivets and placing them securely over the rivets once set in the desired position Figure 3 4 Rear View of the Mounted Node a...

Страница 50: ...50 GigaVUE TA Series Hardware Installation Guide...

Страница 51: ...get you up and running Refer to the following sections for details Grounding the GigaVUE TA Series Chassis on page 52 Connecting Power to the GigaVUE TA Series on page 53 Replacing Fans on page 56 Co...

Страница 52: ...gth 1 2in 1 27cm 3 Connect grounding wire with spade lugs both to the ground screws and to earth ground The specifications for the ground wire and lugs are as follows Standard Wire 14 AWG Stud Size 6...

Страница 53: ...thing The wrist strap protects only the chassis from ESD voltages on the body ESD voltages on clothing can still cause damage Connecting Power to the GigaVUE TA Series The procedure below describes ho...

Страница 54: ...UE TA Series power requirements refer to Power Requirements on page 90 NOTE The GigaVUE TA Series does not have power switches once you connect the system to power it automatically powers on Refer to...

Страница 55: ...the positive and negative power wires to the appropriate terminals using a straight blade screwdriver Connect the positive source wire to the RETURN black terminal using a straight blade screwdriver C...

Страница 56: ...working fan using the procedures in this section To remove a fan 1 Locate lever and handle as shown in Figure 4 7 Figure 4 7 Replacing a Fan GigaVUE TA10 Shown 2 Push lever towards handle 3 Pull on h...

Страница 57: ...isco compatible Refer to B Console Port Signaling and Cabling on page 99 for pinout details 2 Connect the RJ45 end of the console cable to the console port Figure 4 8 Connecting the Console and Manage...

Страница 58: ...t 1 Make the basic power and console cable connections described in Connecting Serial Console and Mgmt Ports on page 57 and power on the GigaVUE TA Series node 2 Start a terminal application on the PC...

Страница 59: ...ord change The system administrator must change the password on the default admin account through the jump start script The default password admin123A is no longer allowed Refer to Run the Jump Start...

Страница 60: ...can use the show serial baudrate command to view the currently configured console port speed Run the Jump Start Script Gigamon provides the GigaVUE nodes with a jump start script that walks you throug...

Страница 61: ...omain name for the node for example mycompany com Default Gateway Supply the IP address of the default gateway for the system DNS Server Supply the IP address of the DNS server for the system Note tha...

Страница 62: ...can also use the username admin password password command to change the admin user s password Refer to Changing the admin Account Password on page 75 Refer to Completing the Initial Setup on page 72 f...

Страница 63: ...n called the GigaVUE TA10 is available with only the first 24 1Gb 10Gb ports enabled The GigaVUE TA10A has serial numbers Gxxxx and product code 132 00D1 A license is needed to expand a GigaVUE TA10A...

Страница 64: ...described in the previous section 2 Wait at least two minutes after the system prompt appears for the system to be initialized and then switch to Configure mode The GigaVUE TA Series node provides th...

Страница 65: ...The GigaVUE OS can operate in one of three modes each with its own set of available commands Standard Enable and Configure When you first launch the CLI you start in Standard mode with access to a li...

Страница 66: ...66 GigaVUE TA Series Hardware Installation Guide...

Страница 67: ...red as is For example if you entered gigastream you would see alias You can build your way through the entire command tree by entering after each new argument For example after entering gigastream ali...

Страница 68: ...ation point at symbol and period characters Those are allowed For example in Config mode port 1 1 q12 alias My_Alias is legal but port 1 1 q12 alias My Alias is not NOTE Some string fields do accept s...

Страница 69: ...for working through the paged output as the Linux programs less and more Press the h key to see paging options Figure 4 11 provides an example If you prefer you can disable paging either for the curre...

Страница 70: ...ure mode coreboot Upgrades the BIOS image on GigaVUE TA100 GigaVUE TA100 CXP GigaVUE HC1 and GigaVUE HC3 crypto Manage X 509 certificates for the node s Web server debug Generate a dump file for use i...

Страница 71: ...clear certain configuration options notifications Configures notification settings ntp Enable and disable the use of NTP as well as add NTP servers ntpdate Set system clock once from a remote server...

Страница 72: ...tion destinations spine link Configures spine links in a cluster with a leaf and spine architecture ssh Enable and disable SSH access as well as manage settings stack link Configure a stack link betwe...

Страница 73: ...configure mode as follows SSH Telnet or Both Both Telnet and SSH2 are available for remote connections to the GigaVUE Traffic Aggregator s Mgmt port By default SSH2 is enabled and Telnet is disabled U...

Страница 74: ...s in fact the GigaVUE node s you can connect over the console port refer to Access the Command Line Interface over the console Port on page 58 and use the show ssh server host keys command to see the...

Страница 75: ...ord for the admin account and add a few other accounts for use by different level users You may have already used the jump start script to change the password for the admin account Changing the admin...

Страница 76: ...annot configure packet distribution or any other global GigaVUE TA Series node options but they can use the show command to review many of the settings in place on the node The following username comm...

Страница 77: ...d idea to configure time manually as well The GigaVUE node will automatically fall back to the manual time setting if it is unable to synchronize with the specified time server The show ntp will show...

Страница 78: ...h the following command config ntp enable 3 The GigaVUE node connects to the specified NTP server and synchronizes to its time 4 NTP reports times in UTC Because of this It is a good idea to specify t...

Страница 79: ...rt 443 Use the following procedure to connect to a GigaVUE node using H VUE NOTE You can configure whether the GigaVUE node redirects all incoming HTTP connections to the HTTPS port with the web http...

Страница 80: ...n c Click the Get Certificate button d Click the Confirm Security Exception button The GigaVUE FM login page appears 4 Enter a valid user name and password and click Login Configuring Internet Explore...

Страница 81: ...ly the email account username and password In this example alerts mycompany com is shown with a password of mypassword123 config email auth username alerts mycompany com config email auth password myp...

Страница 82: ...The name of the factory provided configuration file is initial You can refer to the name of the most recently booted configuration file by using the show running configuration command or show configur...

Страница 83: ...Basic Connections and Configuration 83...

Страница 84: ...84 GigaVUE TA Series Hardware Installation Guide...

Страница 85: ...an optical transceiver the best practice is to wait ten 10 or more seconds before re inserting the same or different optical transceiver Use the show port params all command to see transceiver type i...

Страница 86: ...cause the 40Gb BiDi technology is not compatible with the Gigamon stack protocol Transceiver Installation Instructions Gigamon transceivers are keyed and can only be installed in one direction Transce...

Страница 87: ...TP 12 Position Fiber Cable for Use with SR4 Transceivers This is a female to female Multi fiber Push On MPO Ultra Polished Connector UPC of cable type B Figure 5 1 on page 87 provides cabling details...

Страница 88: ...5 3 MPO MTP 24 Position Fiber Cable Cable Optical Fiber Multimode OM3 50 125 24 Cores Round 3 0mm Tight Aqua Blue OFNP Jacket Connector 2X MTP Female Multimode Aqua Blue Coupling Black Boots 2 P1 Jac...

Страница 89: ...on nodes GigaVUE TA10 GigaVUE TA40 GigaVUE TA100 GigaVUE TA100 CXP and GigaVUE TA200 Compliance for safety emissions and immunity are also provided Refer to the following sections for details Physical...

Страница 90: ...ears Metal to Metal 18 12in 46 0cm Including latches 19 25in 48 89cm 19 05lb 8 64kg GigaVUE TA40 with mounting brackets 1 74in 1RU 4 42cm 19 00in 48 26cm with ears 17 32in 44cm without ears Metal to...

Страница 91: ...t Current 24A 40 5V Table B 3 Power Requirements for GigaVUE TA100 and GigaVUE TA100 CXP Power Configurations 1 1 Power 2 Power Supply Modules Max Power Consumption Heat Output 550 Watts 1892 7 BTU hr...

Страница 92: ...zes the environmental specifications for the GigaVUE TA100 GigaVUE TA100 CXP and GigaVUE TA200 Table B 5 GigaVUE TA100 and TA100 CXP Fan Tray Specifications Rated Voltage 12V DC Input Power Maximum 18...

Страница 93: ...tions UL 60950 1 2nd Edition CAN CSA C22 2 No 60950 1 07 2nd Edition EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 IEC 60950 1 2005 2nd Edition Am 1 2009 Am 2 2013 BSMI GigaVUE TA100 and GigaVUE T...

Страница 94: ...EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EN61000 3 2 EN61000 3 3 Environmental GigaVUE Traffic Aggregation nodes are compliant with the following environmen...

Страница 95: ...available for GigaVUE TA10 and GigaVUE TA40 Refer to Common Criteria in the GigaVUE OS CLI User s Guide BSMI RoHS The RoHS label for Taiwan BSMI for GigaVUE TA200 is as follows VCCI The Class A Inform...

Страница 96: ...nology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may occur in which case the user may be required to take corrective action Warranty Gigamon offers a range o...

Страница 97: ...A GigaVUE TA Series Specifications 97 GigaVUE TA40 GigaVUE TA100...

Страница 98: ...98 GigaVUE TA Series Hardware Installation Guide GigaVUE TA100 CXP GigaVUE TA200...

Страница 99: ...45 rollover cable and RJ 45 to DB 9 adapter provided with the GigaVUE Traffic Aggregator for connections from the system s console port to a PC s COM port The figure below shows how to connect the RJ...

Страница 100: ...onnection illustrated above Console Port from RJ45 Jack RJ 45 to RJ 45 Rollover Cable RJ 45 to DB 9 Terminal Adapter Console Device on PC Signal RJ 45 Pin RJ 45 Pin DB 9 Pin Signal N A 1 8 8 N A N A 2...

Страница 101: ...ra connection for GigaVUE TA10 WARNING The intra building ports RJ45 Management port Console port 1G 10G SFP SFP X1 X48 40G QSFP Q1 Q4 GigaVUE TA10 equipment or subassembly are suitable for connection...

Страница 102: ...wiring or cabling only The intra building port s of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring These interfaces are designed f...

Страница 103: ...ion to the Central Office and CPE Bonding of Battery Return BR Input Terminals The battery returns of the GigaVUE TA10 GigaVUE TA40 GigaVUE TA100 or GigaVUE TA200 shall be connected as DC I Connection...

Страница 104: ...f torque to secure it to the frame and EUT Only listed two hole compression type connectors shall be used in making connection to flat surfaces such as bus bars frames racks or cabinets Torquing and b...

Страница 105: ...d perform the initial configuration of GigaVUE HC1 nodes Also provides reference information for the GigaVUE HC1 node including specifications GigaVUE HC2 Hardware Installation Guide Describes how to...

Страница 106: ...Configuration Guide GigaVUE Cloud Suite for OpenStack Configuration Guide GigaVUE Cloud Suite for Kubernetes Container Configuration Guide GigaVUE Cloud Suite for AnyCloud Configuration Guide Describ...

Страница 107: ...rtise ask questions build their network and learn about best practices for Gigamon products Visit the Gigamon Community site to Find knowledge base articles and documentation Ask and answer questions...

Страница 108: ...108 GigaVUE TA Series Hardware Installation Guide Register today at community gigamon com Questions Contact our Community team at community gigamon com...

Отзывы: