TSA 160 NT
46
Service menu
23.5.3 Mode of operation
Designation
Setting values
Explanation
Mode of operation
Off
Operating mode setting
Night mode
Exit only
Automatic
Hold open
Opening type
2-leaf Open
Open active and passive leaves at activation
1-leaf Open
Only active leaf opens
Open door
Opening of the door via ST220
(press button
1×)
23.5.4 Door parameters
Designation
Setting values
Explanation
Number of leaves
1-leaf drive
2-leaf active
Active leaf drive
2-leaf passive
passive leaf drive
Drive type
Unknown
TSA 160 NT
TSA 160 NT Z
Z Pulling
TSA 160 NT F
F Fire protection
TSA 160 NT Invers
TSA 160 NT Z Invers
Type of installation
Unknown
KM
Transom installation
BS
Hinge side
BG
Opposite hinge side
GLS
Guide rail
GST
Link arm
KM BS GLS
KM BG GST
Drive ser. no.
000000000000
Entry of the serial number:
Change value with
and
,
confirm with
,
cancel with
.
Maintenance
by operating time
0 …
12
… 99
months
Change value with
and
,
confirm with
,
cancel with
.
by cycles
0 …
500,000
…
3,000,000
Cycles
Electric strike type
No electric strike
Fail-secure
Fail-safe
Motor lock
Working close pressure
Only with TSA 160 NT Invers: The electric
strike is relieved through close pressure of
the door leaf before opening.
Closed-circuit current
close pressure
Motor close pressure
Opening delay
0
...20
s
Period which the motor lock has to unlock
before the drive opens the door.
Solenoid valve
Only with TSA 160 NT Invers
No
Door is kept in closing position by electric
strike. Solenoid valve de-energised.
Yes
Door is kept in closing position by sole-
noid valve.