Push And Go
10 Push And Go
WARNING
Danger of injury due to crushing and shearing!
X
During an activated Push And Go function door handles can form crushing and shearing points.
à
The Push And Go function allows activation of the drive without contact sensors being used.
à
When the Push And Go function is set, the drive opens the door automatically as soon as the door leaf is
moved manually out of the closing position.
TSA 160 NT Invers:
à
The closing position limit switch (blue cam, see chapter 17.1, “Open position”) triggers the Push And Go function
at the same time. Connection of an additional closing position limit switch is not necessary.
TSA 160 NT:
à
The Push And Go function is only possible with closing position limit switch (see chapter 11.10, “Closing position
monitoring, closing position blanking SIS, Push And Go”).
à
Setting the parameters:
à
DPS: Set
pU
to value
0 0
for Off,
01 for On.
à
ST220: Set “Movement parameters”, “Push and Go” to the desired function on/
off
.
à
S1, S2: Set parameter 31 to value 00 for Off, 01 for On.
For TSA 160 NT Invers set parameter 30 (
®u
) “Solenoid valve” to 00 “no” in addition.
11 Configurable inputs
à
Various special functions are assigned to the configurable inputs PE1 and PE2 (see chapter 23, “Service menu”).
The contact type required for the desired function is specified in the service menu DPS or service menu ST220 section.
à
The configurable input PE1 is only suitable for connection of normally opened or normally closed contacts.
à
The configurable input PE2 is suitable for connection of normally opened or normally closed contacts as well
as for connection of the monitored analogue signals emergency locking and stop.
à
Setting the parameters:
à
DPS: Set
e1
or
e2
to the desired function.
à
ST220: Set “PE1”, “PE1 function“ or ”PE2”, “PE2 function” to the desired function.
à
S1, S2: Set parameter 17 or 18 to the desired function.
11.1 MPS
See chapter 13.2, “Mechanical programme switch (MPS, external programme switch)”
An MPS can only be connected to PE2.
11.2 Opening 2-leaf and 1-leaf
à
The configurable inputs of the active leaf control can be used to change between the operating modes 2-leaf
opening or 1-leaf opening as required (depending on the parameter setting). This can, for example, be advis-
able if the type of opening is switched by a timer via the available programme switching inputs (AU, DO).
à
It is only possible to change the type of opening when the internal programme switch of the passive leaf drive
is set to the OFF position (“0”).
à
If the analogue programme switch MPS is connected, the type of opening cannot be changed through the
configurable inputs since the MPS specifies “2-leaf opening” or “1-leaf opening” as fixed.
à
Setting the parameters:
à
DPS: Set
e1
or
e2
to
0 3
(“selector switch summer”) or
0 4
(“selector switch winter”).
à
ST220: Set the “PE1 function” or “PE2 function” to “selector switch summer” or “selector switch winter”.
à
S1, S2: Set parameter 17 or 18 to value 03 for “selector switch summer” or value 4 for “selector switch winter”.
51 PE1
2 24V
PE1
52 PE2
PE2
or