Display programme switch DPS and Service push buttons S1, S2
no. DPS Service-LEDs
Parameter
Value
1
ST220 display
Explanation
5
4
3
2
1
20
TO
**
○ ● ○ ●
Electric strike type
00
01
02
03
04
05
06
No electric strike
Fail-secure
Fail-safe
Motor lock
Working close pressure
Static close pressure
Motor close pressure
2)
21
®®
**
○ ● ● ○
Bar message
01
02
Normally opened contact
Normally closed contact
22
D l
**
○ ● ● ●
Opening delay
00
s … 20 s
only with closing
position limit switch
23
hl
**
● ○ ○ ●
Motor follow-up time
0
… 1 … 10 … 20 … 50 × 0.1 s
Can only be set for
TSA 160 NT Invers.
After the limit switch
has been reached the
motor is activated
again for the duration
of the run-on time set.
24
sp
**
● ○ ○ ○
Language
00
01
02
03
deutsch
english
francais
svensk
25
sT
**
● ○ ○ ●
Control type
50
DCU
26
ep
**
● ○ ● ○
Display of the software version
e.g. 03 - 00 - 00 for V1.4
27
h T
**
● ○ ● ●
Type of installation
0
1
2
3
4
Unknown
KM BS GLS
Not used
Not used
KM BG GST
28
fl
**
● ● ○ ○
Activation delay passive leaf
0.1 s …
0.5 s
… 5.0 s
0.1 s
29
a T
**
● ● ○ ●
Drive type
0
1
2
3
4
5
6
Unknown
TSA 160 NT
TSA 160 NT Z
TSA 160 NT F
Not used
TSA 160 NT Invers
TSA 160 NT Z Invers
30
®u
**
● ● ● ○
Solenoid valve (TSA 160 NT Invers) 00
01
No
Yes
31
pU
**
● ● ● ●
Push and Go
00
01
No
Yes
Only with closing
position limit switch
32
cp
*** ● ○ ○ ○
Reset to factory settings
00
01
No
Yes
33
e®
currently queued fault
Display of the faults
34
O e
The displays of the
menu items 34,
35 and 36 are not
available via the
service LEDs, only
via DPS and ST220
Fault memory (the last 10 faults)
Display of the deleted faults
(Fault History)
35
sa
Statistics
Co
Ho
So
Number of cycles / 100
Operating hours / 4
Operating hours / 4 until
next service
Display 6-digits each
Page forwards with
36
cs
Switch off service LED
cS