TSA 160 NT
18
Mechanical contact
5.4.2 Monitoring opening
X
Setting the contact type parameter:
à
DPS: Set
s3
to
0 2
(“normally closed contact”)
(factory setting).
à
ST220: Set the “Input signals”, “SI3 – terminal
SIO” and “SI3 contact type”
to “normally closed contact”
(factory setting).
à
S1, S2: Set parameter 9 to 02 “normally closed
contact”.
X
Setting the function parameter:
à
DPS: Set
f3
to
0 5
(SIO stop) or
0 6
SIO stop SF GF“).
à
ST220: Set the “Input signals”, “SI3 – terminal
SIO”, “SI3 function” to “SIO stop” or “SIO
stop SF GF”.
à
S1, S2: Set parameter 10 to 05 “SIO Stop” or 06
(SIO stop SF GF).
1
GND
13
SIO
10
TST
2
24V
SIO
6
5
4
3
+ 2
- 1
60mA
Test
2
1
3
1
GC 335 slaves
2
Door transmission cable
3
GC 335 master hinge side
5.4.3 Monitoring closing
X
Setting the contact type parameter:
à
DPS: Set
s1
to
0 2
(“normally closed contact”)
(factory setting).
à
ST220: Set the “Input signals”, “SI1 – terminal
SIS” and “SI1 contact type” to “normally
closed contact” (factory setting).
à
S1, S2: Set parameter 7 to 02 “normally closed
contact”.
X
Setting the function parameter:
à
DPS: Set
f1
to the desired function.
à
ST220: Set the “Input signals”, “SI1 – terminal
SIS” and “SI1 function” to the desired
function.
à
S1, S2: Set parameter 8 to the desired function.
1
GND
11
SIS
10
TST
2
24V
SIS
6
5
4
3
+ 2
- 1
60mA
Test
2
1
3
1
GC 335 slaves
2
Door transmission cable
3
GC 335 master opposite hinge side
6
Mechanical contact
à
The input KB is active in the operating modes AU, LS and NA.
à
In the case of 2-leaf systems the mechanical contact can be connected to the active leaf control or to the passive
leaf control.
à
On selection the active leaf opens and, if switched on, the passive leaf.
à
Upon activation, the output of the mechanical contact is closed (24 V applied at the KB input).
à
Setting the contact type parameter:
à
DPS:
Set
cB
to
01
for “normally opened contact” or to
0 2
for “normally closed contact”.
à
ST220: Set the “Signals”, “Input signals”, “KB”, “KB contact type” to “normally opened contact” or “normally
closed contact”.
à
S1, S2: Set parameter 12 to 01 for “normally opened contact” or 02 for “normally closed contact”.
à
A general activation delay (
Dl
, “Opening delay”) can be set for the input. The connection of a closing position limit
switch is necessary for this (see chapter “Closing position monitoring, closing position blanking SIS, Push And Go“).
Setting:
à
DPS:
Set
D l
to the desired delay time (0 s ... 20 s).
à
ST220: Use the buttons
or
to set the “Door parameters”, “Opening delay” to the desired activation
delay (0 s … 20 s) and press
.
à
S1, S2: Set parameter 22 to the desired opening delay (0 s … 20 s).