TSA 160 NT
24
Configurable inputs
11.5.2 Switch function hold-open time (OHZ)
In the case of 2-leaf drives, the settings on the active leaf control determine the hold-open time.
Setting the parameters:
à
DPS: Set
e1
or
e2
to
11
(switch function OHZ NO) for:
1st switch contact = open door / 2nd switch contact = close door
If the SIO is triggered before the hold-open time or the 2nd switch contact is activated, the hold-open
time runs out and is not cancelled by the 2nd switch contact.
The door closes at the latest after the hold-open time has expired:
à
Oh
for 2-leaf drive and 2-leaf mode of operation, if the push button on the passive leaf drive is connected.
à
O ®
for 1-leaf drive or 2-leaf drive and “1-leaf” mode of operation if the push button is connected
to the GF drive.
à
ST220: Set “PE1” or “PE2 function” to “Switch function OHZ NO” for:
1st switch contact = open door / 2nd switch contact = close door
The door closes at the latest after the hold-open time has expired.
à
S1, S2: Set parameter 17 or 18 to value 11 for:
1st switch contact = open door / 2nd switch contact = close door
The door closes at the latest after the hold-open time has expired.
11.6 Control reset
à
The control can be reinitialised via the configurable inputs. After the push button has been activated,
the drive behaves like after the mains voltage has been switched on.
à
Set the parameters with:
à
DPS: Set
e1
or
e2
to
1 3
(reset switch).
à
ST220: Set “PE1 function” or “PE2 function” to “Reset switch NO”.
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
or
11.7 Double push button (1-leaf / 2-leaf door opening)
à
In the case of 2-leaf drives the door can open via the configurable inputs of the active leaf control in 1-leaf
or 2-leaf mode as desired by pressing a button if the “1-leaf opening” operating mode setting is active. If the
push button is pressed once, only the active leaf opens and closes after the 1-leaf hold-open time has expired.
With two successive push button activations within 1.5 s open active leaf and passive leaf and close after the
hold-open time 2-leaf has expired.
à
Set the parameters with:
à
DPS: Set
e1
or
e2
to
1 4
(double push button).
à
ST220: Set “PE1 function” or “PE2 function” to “Double push button”.
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
or
Содержание TSA 160 NT F