TSA 160 NT
10
Safety sensor open and close
5.1.1 Monitoring closing and opening
X
Setting the parameter contact type:
à
DPS:
Set
s1
and
s3
to
0 2
(“normally closed contact”)
(factory setting).
à
ST220: Set the “Input signals”, “SI1 – terminal
SIS”, “SI1 contact type” to “normally
closed contact” and
“SI3 – terminal SIO”, “SI3 contact type”
to “normally closed contact”
(factory setting).
à
S1, S2: Set parameter 7 and 9 to 02 “normally
closed contact”.
X
Setting the function parameter:
à
DPS: Set
f1
to the desired function and
f3
to
0 5
(SIO stop) or
0 6
SIO stop SF GF).
à
ST220: Set the “Input signals”, “SI1 – terminal SIS”,
“SI1 function” to the desired function
and
“SI3 – terminal SIO”, “SI3 function” to “SIO
stop” or “SIO stop SF GF”.
à
S1, S1: Set parameter 8 to the desired function.
Set parameter 10 to 05 “SIO Stop” or 06
“SIO stop GF”.
1
Opposite hinge side
2
Hinge side
3
Door transmission cable
4
GC 338 interface module
S
E
GY
2
1
4
3
5
BN
BK
BU
WH
SIGNAL
24V
SIO
GND
SIS
100mA
S
1
13
10
2
SIO
SIO
GND
24V
TST
1
11
10
2
SIS
SIS
GND
24V
TST
E
or
1
2
3
4
2
1