Comfort Heat Australia © 2020
www.
comfortheat
.com.au
Comfort
Heat
Hydronic & Electric Floor Heating Systems
MWD5 MANUAL - HYDRONIC
SUGGESTED TEMPERATURE SETTINGS
AREAS
TIMBER FLOORING
RADIATORS
SUGGESTED FLOOR TEMP.
24ºC max.
SUGGESTED AIR TEMP.
21-25ºC
21-24ºC
SLAB/TILE/CARPET FLOORING
PRIOR TO TURNING ON
Concrete slabs and screeds must be fully cured before turning the floor heating system on. Wait at least 3 weeks and
when turning on for the first time, increase the floor temperature gradually over 2-3 days.
Under timber and radiators systems can be turned on once installation is complete.
MWD5 DETAILS
The MWD5 WiFi touch screen thermostat has a built in programmable time-clock to automatically turn the heating system
UP and DOWN at selected times.
During the DOWN periods the floor does not turn OFF but programs the floor temperature to a setback temperature.
The floor is heating when the LCD display temperature turns red. Thermostats can be vertically or horizontally flush
mounted and have a 2 pole isolator with 16A output relay.
A Comfort Heat heating system has been installed in your floor. Floor heating warms from the
ground up providing an unparalleled feeling of comfort. This heating system is controlled by an
electronic thermostat and floor sensor for optimum temperature control.
Comfort Heat Australia © 2020
TECHNICAL DATA - MWD5
Supply Voltage : 240V AC, 50/60hz
Output Relay : 16A SPST, 3600W max
Switching Differential : 0.4 degC
Built-in Switch : 2 pole 16A
Temperature Range : 0/+40 degC
Clock Function : Up to 7 different 4 or 6 event
program combinations
Display : 220 x 176 pixel TFT - colour touch
Housing/protection : IP21
Dimensions (HxWxD) : 114mm x 84mm x 40mm
Mounted : Vertical or Horizontal
Thermostat Warranty : 2 years