Introduction & Specifications
SC-ADT Applications Overview
1-8
SpectraComm ADT
076R172-000
Installation and Operation Manual
Issue 6
SC-ADT Applications Overview
The SpectraComm Asynchronous Data Transfer device (SC-ADT) is designed primarily for
Terminal Server and Asynchronous Data Transport over IP applications. NEBS-compliant SC-
ADT can be deployed anywhere in the network where asynchronous devices, craft port equipment,
dry contact devices or contact relay devices are located.
•
From the Management Station, all SC-ADT units are managed via Telnet, SNMP, and HTTP.
Password-protected local and dial-in access is also supported.
•
At SC-ADT sites, some async ports can be configured as terminal server ports, some to
exchange async data with other sites, some for external modem connections, some as contact
sense inputs.
•
The rear panel DB-25 interface provides contact input connections to external devices. SC-
ADT detects state changes and can be configured to send contact alarm traps to an SNMP
controller. This interface also provides output connections for opening or closing a circuit that
applies a specific operational state at the external device.
shows the SC-ADT at remote sites supporting multiple applications simultaneously.
Each application is detailed in the pages that follow the figure.
Figure 1-2
SpectraComm ADT End-to-End Applications (Shown SC-ADT 16-Port Device)
Contact Inputs
1 - 8
Contact Outputs
1 - 2
Contact Inputs
1 - 8
Contact Outputs
1 - 2
Contact Inputs
1 - 8
Contact Outputs
1 - 2
REMOTE SITE 'A'
Remote Sites 'A' and 'B' - SC-ADT 16-port device with integral modem.
Remote Site 'B' - SC-ADT 16-port device with integral modem and SCIP router.
Remote Site 'C' - SC-ADT 16-port device with external modem and bypass modem mode.
All Sites: Any unused front panel port can also be configured for Contact Inputs.
MANAGEMENT
STATION
DIAL-IN USERS
Alternate path via
Dial-up to remote
SC-ADT devices
with internal or
external modems.
ROUTER
or SCIP
Authenticated Dial-up
access to any remote
SC-ADT with modem.
REMOTE SITE 'B'
REMOTE SITE 'C'
Authenticated craft
access to any
local SC-ADT.
LOCAL USER
IP
NETWORK
ROUTER
or SCIP
Authenticated Telnet
access to any SC-ADT
via Ethernet LAN or
dial-up networking (PPP).
TELNET USER
Term Serv
Ports 9 - 16
Async Ports 1 - 8
General
DataComm
1
8
2
3
4
5
6
7
ON
AL
INS
TM
ENET
1
MDM
1
MDM
2
9
16
10
11
12
13
14
15
SC ADT
1-8
9-16
POR
T
Contact Inputs
(Sense or Range)
Ports 9 - 16
Async Ports 1 - 3
Term Serv Ports 4 - 8
1
8
2
3
4
5
6
7
ON
AL
INS
TM
ENET
1
MDM
1
MDM
2
9
16
10
11
12
13
14
15
SC ADT
1-8
9-16
POR
T
PSTN
SCIP
Term Serv Ports 9 - 16
Term Serv
Ports 2 - 8
1
8
2
3
4
5
6
7
ON
AL
INS
TM
ENET
1
MDM
1
MDM
2
9
16
10
11
12
13
14
15
SC ADT
1-8
9-16
POR
T
EXT. MODEM
Port 2 Async
(to ext. modem)
Port 1 Bypass
Transport