SC-ADT Configuration
Port Configuration
3-14
SpectraComm ADT
076R172-000
Installation and Operation Manual
Issue 6
Note
For Transport applications, the
ports enable
command is automatically sent to the remote device.
6. Configure the communication rate for each Terminal Server port for compatibility with the
attached device. The default value is 9600.
configure ports comms port
[#]
For example:
configure ports comms port1 19200
7. Configure the flow control for any port as XON, XOFF, Hardware, or None, by typing:
configure ports flow-control port
[n] or
all
For example:
configure ports flow-control port6 None
8. If required by your network application, configure one or more ports for Datakit simulation, as
follows:
configure ports msgs disable port
[n]
configure ports tel-opt disable port
[n]
configure ports datakit enable port
[n]
Note
Datakit legacy applications cannot tolerate user data to/from the connected async port. Hence, each port
configured for Datakit simulation must have status messages disabled and Telnet negotiation disabled.