SC-ADT Configuration
Port Configuration
3-24
SpectraComm ADT
076R172-000
Installation and Operation Manual
Issue 6
Dialin Port Configuration Procedures
1. Set the desired front panel port to Dialin mode as follows:
configure dialin port
[0, 1, 2, or all]
2. Set the primary Telnet server IP address as follows:
configure dialin pri-ip-address port
[n or all]
[###.###.###.###] [###.###.###.###]
For example:
configure dialin pri-ip-address port3 172.016.009.118 255.255.255.0
3. Optionally, set the backup Telnet server IP address as follows:
configure dialin bak-ip-address port
[n or all]
[###.###.###.###] [###.###.###.###]
4. Set the communications parameters for the Dialin port in a single command string.
For example:
configure ports comms port7 115200 8N1
where port number is (0, 1, 2 ... n, or all)
where Baud Rate is (300 to 115200)
Values may also be set in this string for additional comms parameters (optional):
Data Bits (5, 6, 7 or 8)
Parity (None, Even, Odd, Space or Mark)
Stop Bits (1 or 2)
5. Turn Monitor mode OFF for the Dialin port:
configure ports monitor disable port
(0, 1, 2 ... n, or all)
6. Enter the following command from the ADT’s CLI root menu for each configured Telnet
server. This command will test that a configured Telnet server is reachable and can accept a
Telnet client from the ADT.
telnet
[Remote device IP address]
7. To clear server IPs for Dialin, type:
clear
[Remote device IP address]
8. To force a disconnect of any Dialin port or modem, type:
configure dialin disconnect port
(0, 1, 2 ... n, or all)
9. When all desired ports have been adequately configured for Dialin mode as required, check the
configuration by typing:
show dialin
Figure 3-9
Dialin Show Display
ADT-8% show dialin
______________________Dialin Parameters________________________________________
Port
Dialin
Telnet
Primary Telnet
Backup Telnet
Name
Mode
Status
Status
Server IP Address
Server IP Address
------ ------ ---------- ---------- ----------------- -------------------------
port1 Term --
--
port2 Dialin
Wait
Disc
Idle
172.016.009.181
172.016.011.025
port3 Term --
--
port4 Dialin
Wait
Disc
Idle
172.016.010.161
port5 Dialin
Wait
Conn
Idle
172.016.010.162
172.016.011.025
port6 Term --
--
port7 Term --
--
port8 Tport
--
--
Содержание SC-ADT 16 Por