Application Guidelines
General Application Information
076R172-000
SpectraComm ADT
A-3
Issue 6
Installation and Operation Manual
Modem1 ip-address
IP address (a.b.c.d)
192.168.11.148
IP mask (a.b.c.d)
255.255.255.128
IP broadcast address (a.b.c.d)
(optional)
255.255.255.255
Modem mode
Sets modem0 and modem1
independently for auto-ans or
callback
Auto-answer
or callback
Modem use
Sets modem0 and modem1
independently for use of an
internal or external modem, or for
bypass modem mode
Internal
or external or bypass
Modem bypass
Sets modem0 and modem1
parameters for IP transport via an
attached customer provided IP
device.
Bypass rate for both modem interfaces: 2400,
4800,
9600
, 19200. 38400, 57600, or
115200
Disconnect from DTE on loss of
RTS
or DTR
UDP-Port set 2100 to 65535
IP Gateway address (a.b.c.d)
Modem callback
Authenticates on callback
Enable or
Disable
Add a phone number (No default)
Modem caller-id
Validates the telco-provided phone
number against the Caller-ID list.
Enable or
Disable
Modem authentication
Authenticates username and
password at the modem interface.
Enable or
Disable
Modem inactivity
Disconnects modem1 or modem2
session after the desired interval
(in secs) has elapsed.
120 to 10,000, use 0 to disable
900
Ethernet0 access
Sets the access to the Ethernet0
interface
Enable
or Disable
Modem0 access
Sets the access to the Modem0
interface
Enable
or Disable
Modem1 access
Sets the access to the Modem1
interface
Enable
or Disable
Contact sense
Configures normal state of contact
Normally open
(
NO
) or
Normally closed (NC)
Contact description
Describes the purpose of contact
(No default)
Port authentication
Sets port to require username and
passwords for access
Enable
or Disable
Port acl
Manages IP addresses in access
control list
IP address (a.b.c.d)
Port alert
Defines an alert string by port.
Port name (port1, port2 ... portN)
A quoted string; 30 chars max (no defaults
Port log
Logs port connect/disconnect
message
Enable
or Disable
Table A-1
Configuration Parameters and Defaults
Configurable Option
Description
Parameters and Defaults
Содержание SC-ADT 16 Por
Страница 6: ...iv SpectraCommADT 076R172 000 Installation and Operation Manual Issue 6 Table of Contents...
Страница 92: ...Additional Features SNMP Traps 5 24 SpectraCommADT 076R172 000 Installation and Operation Manual Issue 6...
Страница 105: ......
Страница 106: ...The Best Connections in the Business...