[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 240
ARTDrive V2 series - Instruction Manual
Speed ref
Speed 0 ref thr
DC brake current
0
DC brake
dela
y
Speed 0 ref dl
y
+ Brake close dl
y
t
1
A
B
DC brake
duration
DC brake state
Output current
DC brake cmd src
A = DC brake delay + DC brake duration > Spd 0 ref dly
B = DC brake delay + DC brake duration < Spd 0 ref dly
Figure I00: DC braking sequence
I00
FUNCTION / DC braking
I00.00 DCbrake cmd src
N/A
RWS
Ipa4000
PList 3
PIN
V-F-S-B
Easy 1836
Ipa 4000 - NULL = Default
It allows to select the origin of the signal to command DC braking function.
ª
ª
ª
ª
ª
Pick List 3
I00.10 DCbrake mode
N/A
RWSZ 0
0/1
DP
V-F-S-B
Easy 1832
[0] Off
[1] At Stop
See description above.