[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 292
ARTDrive V2 series - Instruction Manual
PID I freeze src
PID FF mon
PID PI enab src
PID PI out mon
PI stead
y
thr
PI Iinit gain
PI stead
y
dela
y
PI Pinit gain
PI clamp bot
PI clamp top
PID PI Iock mon
PI I notm gain
PI P notm gain
X
+
+
PI P3 gain %
PI P2 gain %
PI P1 gain %
PI I3 gain %
PI I2 gain %
PI I1 gain %
P
I
REF
(REF)
PIGP tran21 band
PIGP tran32 band
PIGP tran21 h thr
PIGP tran32 l thr
PID FF mon
PI enable
Figure O03-2: PI Control block
The
O03.00 - PID PI enab src
and
O03.01 - PID I freeze src
sources allow to select the
origin of the enabling signals (enable/disable) of the PI function and of the freezing
signals of the regulator Integral section.
O03.02 - PIGP ref src
selects the input signal of the gain Adaptive; the block function
allows to set a three-segment Profile. In the Block it is possible to select, via an internal
selector, three starting multiplication values:
O03.30 - Dig PID Mtl PI 1
,
O03.31 - Dig PID
Mtl PI 2
,
O03.32 - Dig PID Mtl PI 3
, internal values which can be set in the
configurations.
The
O03.12 - PID Mtl PI 3 src
source connects standard the value of
O03.32 - Dig PID
Mtl PI 3
.
O03.10 - PID Mtl PI sel 0
and
O03.11 - PID Mtl PI sel 1
are the sources
selecting the command signals of the internal selector. According to their condition, it is
possible to state a combination determining the equivalent output factor.
The following table lists the factors corresponding to each different combination:
PID Mtl PI sel 1
PID Mtl PI sel 0
PID Mtl PI sel mon
0
0
0
*
0
1
1
Dig PID Mtl PI 1
1
0
2
Dig PID Mtl PI 2
1
1
3
**
Tab par O03
* : The last value calculated by the integral component is stoeed
**: The factor connected to the
PID Mlt PI 3 src
is ACTIVE
Table O03: Output factor combination
Содержание ARTDrive Vector V2 400Vac Series
Страница 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Страница 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Страница 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Страница 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Страница 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Страница 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...