[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 191
REF&RAMP / Jump Ref
The block function operates the motor while avoiding resonance caused by characteristic
frequency references in the customer system machine.
Parameters function allow to set two jump reference frequencies in rpm, with their related
jump bandwidth in rpm too. During motor running at constant-speed, operation within
jump reference frequency [rpm] range is prohibited.
Jump
re
f
2
F
re
q
Re
f
ere
nc
e
In
F
re
q
Re
f
ere
nc
e O
ut
Jump
re
f 1
Jump Band 1 o
r
Jump Band
2
Jump Band
2
Jump Band
2
Jump Band 1
Jump Band 1
Figure D11: Jump frequencies
D11 REF&RAMP / Jump Ref
D11.00 Jump Ref 1
[rpm] RWS
0
0/FSS
PP
V-F-S-B
Easy 345
Jump reference 1 frequency in rpm.
Maximum value setting allowed is equal to
B01.00 - Full scale speed
(Ipa 1885)
D11.01 Jump Band 1
[rpm] RWS
0
0/(**)
PP
V-F-S-B
Easy 346
Jump bandwidth 1 frequency in rpm.
(**) Maximum value setting allowed is equal to:
a) 100 if Full Scale Speed >100
b) FSS if Full Scale Speed <100
FSS =
B01.00 - Full scale speed
(Ipa 1885)
D11.02 Jump Ref 2
[rpm] RWS
0
0/FSS
PP
V-F-S-B
Easy 347
Jump reference 2 frequency in rpm.
Maximum value setting allowed is equal to
B01.00 - Full scale speed
(Ipa 1885).
Содержание ARTDrive Vector V2 400Vac Series
Страница 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Страница 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Страница 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Страница 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Страница 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Страница 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...