INTERFACE / Analog Inputs
The Drive, in its standard version on the regulation card, provides the following analog/
digital I/Os:
-
3 analog inputs (terminals: 1-2, 3-4, 5-6), configured as voltage or current
differential inputs.
-
2 voltage analog outputs (terminals: 21-22-23), with a common reference potential.
-
8 digital inputs (terminals: 12-13-14-15, 36-37-38-39), with a common reference
potential and a galvanic isolation.
-
4 digital outputs (terminals: 41-42, 80-82, 83-85), with a common reference
potential, a common power supply and galvanic isolation.
N
OTE
!
See chapters 4.3.2 and 4.3.3 in the Quick Start Up Guide. Other analog and digital
I/Os are available by using the EXP.. expansion cards, referred with the “X” suffix.
C01 INTERFACE / An Inp 1
The 2 Block sources allow to select the origin of the command signals for the following
functions:
-
“AI 1 sign src” allows the inversion of the output signal
-
“AI 1 alt sel src” allows the selection of an alternative output reference.
The upper and lower limit of the output signal can be set via the
C01.17 - AI 1 hi lim
and
C01.16 - AI 1 lo lim
parameters. This function is shown in the following figure.
The Block has a sampling time of 2 msec. The resolution is: 10V=2047 counts.
+1
-1
(*)
HARDWARE JUMPER
: Off --> AI1 +/- 10V
S8
: On --> AI1 0-20mA ;4 - 20mA
SET BY
An inp 1
AUTOTUNE
SET BY
An inp 1
AUTOTUNE
S
+
+
INPUT
F
AI 1 output
16384
-16384
AI 1 hi lim
AI 1 lo lim
(Input[V] * 16384 /10[V]) * Gain * Scale
(*)
CALIBRATION OF
ANALOG INPUT
AI 1 output
AI 1 t
y
pe
AI 1 filter
AI 1 offset
AI 1 thr
AI 1 scale
AI 1 gain
AI 1 < thr
AI 1 hi lim
AI 1 lo lim
NULL
AI 1 sgn src
AI 1 alt sel src
NULL
AI 1 alt value
S8
Figure C01: Analog input block diagram
C01.00 AI 1 sgn src
N/A
RWS
Ipa4000
PList 3
PIN
V-F-S-B
Full
5011
Ipa 4000 - NULL = Default
It connects the selected signal to the selector of the multiplier input: if the signal is 0,
multiply by +1, or if the signal is 1, multiply by -1. The multiplier allows to invert Analog
Содержание ARTDrive Vector V2 400Vac Series
Страница 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Страница 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Страница 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Страница 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Страница 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Страница 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...