ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 261
ALARM CFG / Alarms status
N
OTE
!
Menu accessible with Access Level = FULL
The alarm state can be reported via three Words. Each bit determines an alarm state.
It is therefore possible to determine the state of 48 alarms. Each single bit can be
controlled if the corresponding bit of a specific mask is set with 1, otherwise their setting
is always 0.
When an alarm becomes active, the word corresponding bit is set with 1.
Its setting remains equal to 1 till the alarm becomes inactive and the “
State Machine
or
Sequencer
” is not in an alarm condition. If the state of a single alarm has to be controlled
via an output, then only the mask needed bit has to be set with 1.
If the state of several alarms has to be controlled via an output, then the mask
corresponding bits have to be set with 1.
The alarms have to be controlled by the Word itself.
I.e.: the state of the External fault alarm has to be read.
Mask W1 S1 = 0x0100 => 0000 0001 0000 0000
Mask W2 S1 = 0x0000 => 0000 0000 0000 0000
Mask W3 S1 = 0x0000 => 0000 0000 0000 0000
DO 0 src = Select ipa Alm W1 S1.
The state of the Undervoltage and Overvoltage alarm has to be read.
Mask W1 S1 = 0x0100 => 0000 0000 0000 0110
Mask W2 S1 = 0x0000 => 0000 0000 0000 0000
Mask W3 S1 = 0x0000 => 0000 0000 0000 0000
DO 0 src = Select ipa Alm W1 S1.
The state of the External fault and F_R_C alarm has to be read.
Mask W1 S1 = 0x0100 => 0000 0001 0000 0000
Mask W2 S1 = 0x0000 => 0000 0000 1000 0000
DO 0 src = Select ipa Alm W1 S1.
DO 1 src = Select ipa Alm W2 S1.
See alarm list below.
L22 ALARM CFG / AL status
Alarm status configuration:
L22.00 Mask W1 S1
N/A
RWS
0XFFF
0 -1
DP
V-F-S-B
Full
9610
L22.01 Mask W2 S1
N/A
RWS
0XFFF
0 -1
DP
V-F-S-B
Full
9611
L22.02 Mask W3 S1
N/A
RWS
0XFFF
0 -1
DP
V-F-S-B
Full
9612
Содержание ARTDrive Vector V2 400Vac Series
Страница 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Страница 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Страница 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Страница 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Страница 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Страница 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...