[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 233
TORQUE / Voltage DC Control Regulator
N
OTE
!
Menu accessible with Access Level = FULL
The function is available only with a Sensorless and Field Oriented regulation mode.
It allows the control:
•
of the DC link voltage during regenerating (ex. deceleration), to avoid the
Overvoltage alarm trip
or
•
the control of the power recovered on the DC link during regenerating
The two functions are activated by setting the following parameters respectively in
the
G01.00 - Tcur lim sel
of the Torque Setpoint:
•
[3] T lim gen pwr
For a control of the recovered power
•
[4] T lim Vdc ctrl
For a control of the DC link voltage
During such phases the
G02.00 - VdcCtrl P gain
and
G02.01 - VdcCtrl I
gain
parameters (gains) allow the tuning, if required, of the DC link control.
G02 TORQUE / VdcCtrReg
G02.00 VdcCtrl P gain
[A/V] RWS
Calc
0/Calc
PP
F-S-B
Full
2295
Proportional gain of Voltage DC Control Regulator.
G02.01 VdcCtrl I gain
[A/V/s] RWS
Calc
0/Calc
PP
F-S-B
Full
2296
Integral gain of Voltage DC Control Regulator.
Содержание ARTDrive Vector V2 400Vac Series
Страница 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Страница 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Страница 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Страница 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Страница 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Страница 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...