![GEFRAN-SIEI ARTDrive Vector V2 400Vac Series Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/gefran-siei/artdrive-vector-v2-400vac-series/artdrive-vector-v2-400vac-series_instruction-manual_2205769158.webp)
Index
MENU
MENU
MENU
MENU
MENU
[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 158
ARTDrive V2 series - Instruction Manual
-
There are no failure alarms present
-
The drive is enabled. The enable operation is defined by parameters
En/disable
mode
&
Commands sel
-
The magnetizing procedure has been completed (Drive is ready to deliver torque)
N
OTE
!
The contact opens immediately on a drive failure, or when the drive is disabled.
Pic
Pic
Pic
Pic
Pick List 1
k List 1
k List 1
k List 1
k List 1
[0] NULL
(Ipa 4000)
[1] ONE
(Ipa 4001)
[2] Vlt search m
(Ipa 3572)
[3] Drive ready
(Ipa 161)
[4] Enable SM m
(Ipa 162)
[5] Start SM mon
(Ipa 163)
[6] FS SM mon
(Ipa 164)
[7] AL Sequencer
(Ipa 9096)
[8] Drive OK
(Ipa 9097)
[9] Jog state
(Ipa 8013)
[10] En cmd mon
(Ipa 150)
[11] Str cmd mon
(Ipa 151)
[12] FS cmd mon
(Ipa 152)
[13] AI 1 < thr
(Ipa 5010)
[14] AI 2 < thr
(Ipa 5030)
[15] AI 3 < thr
(Ipa 5050)
[16] DI 0 En mon
(Ipa 4020)
……(all DI)……
[35] DI 11X mon
(Ipa 4056)
[36] FRC reverse
(Ipa 8081)
[37] RampAcc stat
(Ipa 8023)
[38] RampDec stat
(Ipa 8024)
[39] RampOut != 0
(Ipa 8025)
[40] Spd lim stat
(Ipa 7049)
[41] Spd is zero
(Ipa 3728)
[42] Ref is zero
(Ipa 3729)
[43] Spd is 0 dly
(Ipa 3730)
[44] Ref is 0 dly
(Ipa 3731)
[45] TcurLim stat
(Ipa 2445)
[46] SpdTrq ctrl
(Ipa 2446)
[47] DCbrake stat
(Ipa 1837)
[48] PLR active
(Ipa 2284)
[49] PLS active
(Ipa 2275)
[50] PLS Tout act
(Ipa 2276)
[51] Drv OL trip
(Ipa 1570)
[52] Drv OL warn
(Ipa 1580)
[53] Mot OL trip
(Ipa 1680)
[54] BU OL trip
(Ipa 1782)
[56] ActSpdFbkSel
(Ipa 1941)
[57] Std enc fail
(Ipa 3224)
[58] Exp enc fail
(Ipa 3225)
[59] Alm W1 S1
(Ipa 9630)
..(all AL status)..
[64] Alm W3 S2
(Ipa 9636)
[65] Compare1 out
(Ipa 6048)
[66] Compare2 out
(Ipa 6063)
[67] AI 1X < thr
(Ipa 5068)
[68] AI 2X < thr
(Ipa 5088)
[69] B0 W0 decomp
(Ipa 2123)
..(all Bits W0)..
[84] B15 W0 decom
(Ipa 2138)
[85] B0 W1 decomp
(Ipa 9363)
..(all Bits W1)..
[99] B15 W1 decom
(Ipa 9378)
[100] PL next act
(Ipa 2283)
[101] DiamCalc act
(Ipa 7367)
[102] Dig pad 0
(Ipa 9116)
..(all Dig PAD)..
[117] Dig pad 15
(Ipa 9131)
[118] Mlt par stat
(Ipa 8102)
[119] Mlt p actsel
(Ipa 8104)
Содержание ARTDrive Vector V2 400Vac Series
Страница 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Страница 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Страница 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Страница 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Страница 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Страница 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...