Chapter 6 Parameter • 241
I00.11 DCbrake delay
[sec] RWS
0.5
0.01/30
PP
V-F-S-B
Easy 1833
Delay between the injection command and the injection of the current itself.
I00.20 DCbrake duration
[sec] RWS
1
0.01/30
PP
V-F-S-B
Easy 1834
Duration of the current injection.
I00.21 DCbrake current
[%]
RWS
50
0/100
PP
V-F-S-B
Easy 1835
Braking current as a percentage of Drive continuos current.
I00.22 DCbrake state
N/A
R
0
0/1
DV
V-F-S-B
Easy 1837
[0] non-active
[1] active
State of DC Brake functon.