7-2
W650 Wind Generator Protection System
GEK-113032A
7.1 IEC61850 GENERIC SUBSTATION STATE EVENT (GSSE)
7 IEC 61850 PROTOCOL
7
7.1.1.3 REMOTE DEVICES: ID OF DEVICE FOR RECEIVING GOOSE MESSAGES
Thirty two Remote Devices, numbered from 1 to 16, can be selected for setting purposes. This setting is used to select
specific remote devices by entering the exact identification (ID) assigned to those devices. The Remote Devices can be
displayed in W650 relay:
Actual Values > Input/Outputs > Remote Inputs > Remote Device1(32)
and ONLY programmed and displayed in the EnerVista 650 Setup (see Figure 7–1:)
Setpoint
> Input/Outputs > Remote Comms > Remote Device 1(32)
Actual > Input/Outputs > Remote Inputs > Remote Device1(32)
Figure 7–1: REMOTE COMMUNICATIONS
Содержание Multilin W650
Страница 2: ......
Страница 10: ...VIII W650 Wind Generator Protection System GEK 113032A TABLE OF CONTENTS ...
Страница 30: ...1 20 W650 Wind Generator Protection System GEK 113032A 1 4 W650 HARDWARE 1 GETTING STARTED 1 ...
Страница 140: ...4 72 W650 Wind Generator Protection System GEK 113032A 4 3 WEB SERVER 4 HUMAN INTERFACES 4 ...
Страница 360: ...7 48 W650 Wind Generator Protection System GEK 113032A 7 2 IEC 61850 PROFILE FOR W650 7 IEC 61850 PROTOCOL 7 ...
Страница 368: ...8 8 W650 Wind Generator Protection System GEK 113032A 8 4 OBJECT DICTIONARY 8 W650 CANOPEN PROFILE 8 ...
Страница 406: ...11 22 W650 Wind Generator Protection System GEK 113032A 11 15 RECLOSER 79 11 COMMISSIONING 11 ...
Страница 422: ...13 6 W650 Wind Generator Protection System GEK 113032A 13 4 RELAY CONFIGURATION 13 FREQUENTLY ASKED QUESTIONS 13 ...
Страница 446: ...A 22 W650 Wind Generator Protection System GEK 113032A A 1 LOGIC OPERANDS APPENDIXA A ...
Страница 596: ...D 8 W650 Wind Generator Protection System GEK 113032A D 5 IEC 60870 5 104 POINT LIST APPENDIXD D ...
Страница 622: ...F 2 W650 Wind Generator Protection System GEK 113032A F 1 GE MULTILIN WARRANTY APPENDIXF F ...