GEK-113032A
W650 Wind Generator Protection System
2-5
2 PRODUCT DESCRIPTION
2.3 ORDERING CODE
2
2.3ORDERING CODE
W650 units are supplied as ½ 19” rack, 6 units high, containing the following modules: power supply, CPU, I/O modules,
communication modules. The required information to completely define an W650 model is shown on Table 2–1:
Table 2–1: ORDERING CODE
Notes
:
(1)
The digit selected for option G must be equal or higher than the digit selected for option F:
W650***F1G5*****: is a valid selection
W650***F5G1*****: is an invalid selection
As exceptions to this rule, 0 is always available for option G, and F2G1 is also a valid selection.
W650
-
-
-
F
-
G
-
-
-
-
-
DESCRIPTION
B
Basic display (4x20 characters)
M
Graphic display (240x128 pixels)
REAR SERIAL COMMUNICATIONS BOARD 1
F
None
A
Redundant RS485
P
Redundant plastic fiber optic
G
Redundant glass fiber optic
X
Redundant RS485 + fiber Can port (CANopen)
Y
Redundant plastic fiber optic + fiber Can port (CANopen)
Z
Redundant glass fiber optic + fiber Can port (CANopen)
C
CableCan port (CANopen)
M
Cable can port (CRS485
REAR ETHERNET COMMUNICATIONS BOARD 2
B
10/100 Base TX
C
10/100 Base TX + 100 Base FX
D
10/100 Base TX + Redundant 100 Base FX
E
Redundant 10/100 Base TX
I/O BOARD IN SLOT F
1
16 Digital 8 Outputs
2
8 Digital 8 O 2 trip/close circuit supervision
circuits
4
32 Digital Inputs
5
16 Digital 8 Analog Inputs
I/O BOARD IN SLOT G
0
None
1
16 Digital 8 Outputs
4
32 Digital Inputs (see Note 1)
5
16 Digital 8 Analog Inputs (See Note 1)
AUXILIARY VOLTAGE
LO
24-48 Vdc (range 19.2 – 57.6)
HI
110-250 Vdc (range 88 – 300)
120-230 Vac (range 96 – 250)
LOR
Redundant LO
HIR
Redundant HI
COMMUNICATION PROTOCOL
-
Without IEC 61850 protocol
6
IEC 61850
ENVIRONMENTAL PROTECTION
-
Without Harsh (Chemical) Environment Conformal Coating
H
Harsh (Chemical) Environment Conformal Coating
Содержание Multilin W650
Страница 2: ......
Страница 10: ...VIII W650 Wind Generator Protection System GEK 113032A TABLE OF CONTENTS ...
Страница 30: ...1 20 W650 Wind Generator Protection System GEK 113032A 1 4 W650 HARDWARE 1 GETTING STARTED 1 ...
Страница 140: ...4 72 W650 Wind Generator Protection System GEK 113032A 4 3 WEB SERVER 4 HUMAN INTERFACES 4 ...
Страница 360: ...7 48 W650 Wind Generator Protection System GEK 113032A 7 2 IEC 61850 PROFILE FOR W650 7 IEC 61850 PROTOCOL 7 ...
Страница 368: ...8 8 W650 Wind Generator Protection System GEK 113032A 8 4 OBJECT DICTIONARY 8 W650 CANOPEN PROFILE 8 ...
Страница 406: ...11 22 W650 Wind Generator Protection System GEK 113032A 11 15 RECLOSER 79 11 COMMISSIONING 11 ...
Страница 422: ...13 6 W650 Wind Generator Protection System GEK 113032A 13 4 RELAY CONFIGURATION 13 FREQUENTLY ASKED QUESTIONS 13 ...
Страница 446: ...A 22 W650 Wind Generator Protection System GEK 113032A A 1 LOGIC OPERANDS APPENDIXA A ...
Страница 596: ...D 8 W650 Wind Generator Protection System GEK 113032A D 5 IEC 60870 5 104 POINT LIST APPENDIXD D ...
Страница 622: ...F 2 W650 Wind Generator Protection System GEK 113032A F 1 GE MULTILIN WARRANTY APPENDIXF F ...