4-38
W650 Wind Generator Protection System
GEK-113032A
4.2 HUMAN MACHINE INTERFACE (HMI)
4 HUMAN INTERFACES.
4
4.2.5.2 TEXT MENU HIERARCHY
The structure of HMI text menu is similar to the EnerVista 650 Setup in the actual values and settings (view and change)
menus.
The main menu shows the following options:
Table 4–28: GENERAL OVERVIEW OF MAIN TEXT MENU:
NAME
DESCRIPTION
NAVIGATION IN MENU
Actual Values
Actual values of all the signals available in device.
Status of protection and control elements,
measurements, inputs and outputs, etc.
Press shuttle key to enter next level. Press ESC to
return to default main screen.
Snapshot events
Visualization of all snapshot events in text mode (two
screens for each snapshot event). In graphical displays
there can be seen in a dedicated screen.
Press shuttle key to visualize snapshot events in text
menu. Press ESC to return to default main screen.
Fault Report
Fault reports information available in HMI (two screens
for each fault report)
Press shuttle key to enter next level. Move L-R to see
all the available fault reports in device. Press shuttle
key to enter particular information for fault report
selected.
View Settings
Visualization of all protection and control settings
available in device.
Press shuttle key to enter next level. Move L-R to
select submenu. Press ESC to return to previous
level.
Change Settings
Menu that allows changing all protection and control
settings available in device. Inputs and outputs settings,
relay configuration and logic configuration are not
available in HMI, only via EnerVista 650 Setup
software.
Press shuttle key to enter next level. Move L-R to
select submenu. Press esc to return to previous level.
Date & Time
Date and time visualization and modification by user
First mode is visualization. Press again shuttle key to
start modification in date and time. Press ESC to
return to previous level.
Commands
Operations execution in local mode.
Move L-R to pre select operation. Press shuttle key to
select and confirm. Press ESC to return to previous
level.
Password
Password menu for settings and commands
Move L-R to select submenu. Press shuttle key to
enter next level. Press ESC to return to previous
level.
Select Main Screen
Selection of default main screen in text menu.
Move L-R to select the default main screen type.
Press shuttle key to confirm.
Select Language
Language selection. Between default language (see
ordering code) and English.
Move L-R to select the default language. Press
shuttle key to confirm selection. Switch the relay off
and on.
< - return
Return to previous level
Press shuttle key to return to previous level.
Содержание Multilin W650
Страница 2: ......
Страница 10: ...VIII W650 Wind Generator Protection System GEK 113032A TABLE OF CONTENTS ...
Страница 30: ...1 20 W650 Wind Generator Protection System GEK 113032A 1 4 W650 HARDWARE 1 GETTING STARTED 1 ...
Страница 140: ...4 72 W650 Wind Generator Protection System GEK 113032A 4 3 WEB SERVER 4 HUMAN INTERFACES 4 ...
Страница 360: ...7 48 W650 Wind Generator Protection System GEK 113032A 7 2 IEC 61850 PROFILE FOR W650 7 IEC 61850 PROTOCOL 7 ...
Страница 368: ...8 8 W650 Wind Generator Protection System GEK 113032A 8 4 OBJECT DICTIONARY 8 W650 CANOPEN PROFILE 8 ...
Страница 406: ...11 22 W650 Wind Generator Protection System GEK 113032A 11 15 RECLOSER 79 11 COMMISSIONING 11 ...
Страница 422: ...13 6 W650 Wind Generator Protection System GEK 113032A 13 4 RELAY CONFIGURATION 13 FREQUENTLY ASKED QUESTIONS 13 ...
Страница 446: ...A 22 W650 Wind Generator Protection System GEK 113032A A 1 LOGIC OPERANDS APPENDIXA A ...
Страница 596: ...D 8 W650 Wind Generator Protection System GEK 113032A D 5 IEC 60870 5 104 POINT LIST APPENDIXD D ...
Страница 622: ...F 2 W650 Wind Generator Protection System GEK 113032A F 1 GE MULTILIN WARRANTY APPENDIXF F ...