– 42 –
The thermistor and harness comes as one
assembly that connects to the control board.
The thermistor also comes with an O-ring that
creates a water tight seal around the probe.
When reinstalling the thermistor, ensure that the
thermistor is seated properly. If it bulges, it will not
seal properly.
Thermistor
Bulging O-ring
Thermistor Resistance Table
Temp
(°C)
Temp
(°F)
5HVLVWDQFH
10
50
19901
15
59
15713
20
68
12493
28
82.4
8833
32
90
7446
38
100
5807
44
111
4558
50
122
3601
54
130
3108
66
150
2016
76
169
1435
Bleach/Bulk Tank Funnel
The bleach portion of the funnel directs the liquid
bleach to the top cover, dispensing it between the
outer tub and the basket. There is no water valve
to rinse the funnel after use. The bulk tank portion
of the funnel directs the liquid detergent into the
bulk tank.
Bleach/Bulk Tank Funnel Removal
1. To remove the bleach/bulk tank funnel, reach
between the top cover and tub cover and
push up on the bottom of the funnel.
2. Removing the funnel gives access to the bulk
tanks 3/8 in. mounting bolt.
3. To install the funnel onto the top cover, push
down on the funnel to seat it into position.
Bulk Tan
k
Mounting Bolt