– 18 –
3URGXFW6SHFL¿FDWLRQV
$&9ROWDJH
Main Board
: 120 VAC to the J101
Recirculation Pump
: Should read
approximately 31.7 ohms - 120 VAC
Drain Pump
: Should read approximately
13.2 ohms - 120 VAC
Mode Shifter Motor
: Should read
approximately 5.7k ohms - 120 VAC
Water Valves
: Should read approximately
1.3k ohms – 120 VAC
Lid Lock Position Locked
: Locked pin 3 to
pin 1 approximately 70 ohms - 120 VAC
/LG6ZLWFK3RVLWLRQ&ORVHG
Continuity is
checked between pins 1 and 2 with the lid
closed
Water Levels
)25(/(&75267$7,&6EHVXUHWRPDNHDQHDUWKJURXQGFRQQHF
-
WLRQEHIRUHUHSODFLQJDQ\HOHFWURQLFFRPSRQHQWVWRSUHYHQWHOHF
-
WURVWDWLFGDPDJHWRWKHP7KLVLVGRQHE\WRXFKLQJDJRRGHDUWK
JURXQGRQWKHDSSOLDQFHEHLQJUHSDLUHG
Approximate Minimum Water Levels
Impeller
: 7 gallons or 3 in. deep from the bottom
of the basket.
Approximate Maximum Water Levels
Impeller
: 26 gallons or 13-1/2 in. deep from the
bottom of the basket. Press and hold the
Deep
Fill
button for 3 seconds to achieve.
Impeller
Bulky
setting water level is 26 gallons or
12-3/4 in. deep from the bottom of the basket.
'&9ROWDJH
8,/RJLF%RDUG
: 12 VDC / 7.5 VDC
Hall Sensor
: 9 VDC pin 3 to pin 2
Pressure Sensor
: (See
Pressure Sensor
in the
Fill System
section of this service
guide.)