– 24 –
([SODLQLQJ6HUYLFH0RGH7HVWV
7KHUHDUHGLႇHUHQWWHVWVWKDWFDQEHSHUIRUPHGRQWKHZDVKHUZKLOHLQ6HUYLFH0RGH
Once in the Service Mode, rotate the Cycle Select knob to advance to the desired test.
Knob Index /
Test number
Displayed on
VHJPHQW
display (SSD)
Test Name
Description of test
Turning the cycle knob will index to the next or prior test.
0
All LED’s on
All LEDs on the display will be blink including "88" at a rate of
1Hz.
1
Fault Codes
On Start button press, blink first fault code.
Display fault code in SSD.
At end of list OR if no fault codes are present, washer will flash
"- -".
2
Personality ID
Pressing Start will start the test.
Flash the set personality after pressing
Start
.
(See
Personality ID Numbers
, under
Personality ID
in the
'LDJQRVWLFV
section of this service guide for the correct ID for
the model being checked.)
3
UI Software
Version (Critical)
(Critical)
After entering
this test, press
the
Start
button
to toggle through
the software
version number
as follows:
After entering this test, press the Start button to toggle through
the software version number as follows:
Example
: v01.23
First press: "01" on 7SD
Second press: "23" on 7SD
4
UI Software
Version
(Non-critical)
After entering this test, press the Start button to toggle through
the software version number as follows:
Example
: v01.23
First press: "01" on SSD
Second press: "23" on SSD
5
XML Version
(Non-critical)
Example
: v01.23
First press: "01" on SSD
Second press: "23" on SSD
NOTE
: Only the non-critical version number is shown because
the critical XML version number must match the application non-
critical version number for the control to boot. If service mode is
attained, then the XML critical version is correct. If not, update
the software.
6
Hot Water Valve
Pressing Start will toggle the hot water valve on and off. Test will
have a time-out for how long valve will be on (1 minute). The
valve will turn off when the test is exited.
7
Cold Water Valve Pressing Start will toggle the cold water valve on and off. Test
will have a time-out for how long valve will be on (1 minute). The
valve will turn off when the test is exited.
Service Mode Tests
(Continued next page)