133
FMPC
9.2.24 Processor Temperature
Calibration (467)
This menu is used to calibrate the temperatures of
the solutions in the processing tanks.
The measured temperature should be entered to
prevent deterioration of the solution.
[Selection]
“4 Setup and Maintenance” - “6 Processor
Adjustment/Maintenance” - “7 Processor
Temperature Calibration”
[Procedure]
Perform the processor section temperature
calibrations.
1
Check that the display values reach the “Setting”
temperatures.
2
Open the dryer unit and support it with Stopper 2
(yellow).
3
Open the replenisher box door.
4
Remove the circulation filter tray.
5
Remove the P1 circulation filter and put it into the
circulation filter tray.
6
Measure the temperature of the P1 processing
solution and record it.
Stopper 2 (Yellow)
L
2
236
P1 Circulation Filter
Circulation Filter Tray
L
2
233
Thermometer
P1 Sub-tank
L
2
1047
distributed by www.minilablaser.com
Содержание Frontier 570
Страница 144: ...distributed by www minilablaser com ...