89
FMPC
7
Install each auto-cleaning nozzle into a
measuring vessel.
8
Install the measuring vessels on the processing
rack by aligning their rubber joints with the
washing solution tank holes.
If the rubber joints are not installed properly, the
washing solution will splash.
Push in each measuring cup until its locking hook is
engaged in the rack. If it is installed improperly, the
washing solution will splash.
9
Open the “4 Setup and Maintenance” menu
screen (see Section 8.1).
10
Select “2 Auto-cleaning Output Measurement/
Setting”, and click [START].
• The “[462] Auto-cleaning Output Measurement/
Setting” screen appears.
• The cursor is located on the “Measured value”
for “P1”.
11
Click [Start] for “P1”.
• The alarm beeps intermittently for 10 seconds.
Click [Cancel] to stop the operation.
• The alarm beeps once when the discharging is
completed.
Measuring Vessel
Auto-cleaning Nozzle
EZ1067
Measuring Vessel
Rubber Joint
EZ1068