58
• The “[31] Inspection Item Display” screen
appears.
3
Pull up the release lever as shown in the figure to
release the pressure cover.
4
Use a cotton swab moistened with magnet
cleaner (MC-100) to remove any dirt or dust
adhering to the magnetic heads.
5
Collect the waste solution.
6
Clean around the machine, and then click [OK].
• The “Production Information” screen appears.
Select the “Negative”, “Reversal”, “Digital Image” or
“All” from the “Input Type” box to display production
information respectively.
IMPORTANT
The printing information from the DSC import is
not counted in this screen. Check and save this
information in the “Production Information” in the
FMPC.
Release Lever
Pressure Cover
EZ1156
Magnetic Head
Swab
EZ1161
F350/370
distributed by www.minilablaser.com