![Fuji Electric FRENIC-VG Series Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/fuji-electric/frenic-vg-series/frenic-vg-series_user-manual_2341868065.webp)
5.4 FRENIC-VG Loader
5-45
Chap. 5
USING ST
ANDARD RS-
485
5.4 FRENIC-VG
Loader
Inverter support software FRENIC-VG Loader runs on a computer to provide the following.
• Configuring and managing function codes: Reading/writing function code data from/to the
inverter
• Monitoring the running status of the FRENIC-VG:
Operation monitor (I/O monitor and system monitor)
Trace functions (Real-time trace and historical trace)
• Analyzing failures that have happened in the FRENIC-VG:
Operation monitor (Alarm monitor)
Trace functions (Traceback)
Using the above functions of FRENIC-VG Loader enables you to easily start FRENIC-VG, manage
function codes, and analyze failures without setting up a data logger tool.
FRENIC-VG Loader is available in two versions: Free version (WPS-VG1-STR) included in the
CD-ROM that comes with the FRENIC-VG inverter and Optional paid-for version
(WPS-VG1-PCL).
For details, refer to the FRENIC-VG Loader Instruction Manual.
FRENIC-VG Loader functions supported by free version and paid-for version
Reading/writing function code data
Traceback
Supported by free version
WPS-VG1-STR
(Instruction Manual
INR-SI47-1617*-
)
Historical trace
Trace functions
Real-time trace
I/O monitor
System monitor
Operation monitor
Alarm monitor
--
Supported by optional paid-for
version WPS-VG1-PCL
(Instruction Manual
INR-SI47-1589*-
)
On non-standard series of inverters such as special order-made inverters, FRENIC-VG
Loader may not display some function codes normally.
5.4.1 Specifications
Item Specifications Remarks
Supported inverter series
FRENIC-VG (Unit and stack types)
FRENIC5000VG7
Direct connection
with the inverter
USB connection: 1 inverter only
RS-485 connection: Max. 31 inverters
Direct connection between
Loader and inverter via the USB
or RS-485 interface.
Connection
Via-PLC
communication *1
Via USB
Via RS-485
Via communications board (Ethernet interface)
Connection between Loader and
PLC (MICREX-SX).
Recommended cables
USB: USB cable (Mini B connector)
RS-485: Shielded twisted pair for
long-distance transmission
*1 In the system configuration in which the FRENIC-VG (or FRENIC5000VG7) inverter is connected with the
MICREX-SX via the SX bus (or E-SX bus), connecting FRENIC-VG Loader to the MICREX-SX enables access
to the inverter.
Содержание FRENIC-VG Series
Страница 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Страница 2: ......
Страница 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Страница 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Страница 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Страница 203: ...6 6 High Speed Serial Communication Capable Terminal Block 6 127 Chap 6 CONTROL OPTIONS Figure 6 6 3 ...
Страница 234: ...6 158 6 7 3 External dimension drawing 17 Unit mm Figure 6 7 5 Option PCB Outline Drawing Tightening torque 0 4 N m ...
Страница 344: ......
Страница 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...