6.7 CC-Link Interface Card
6-181
Chap. 6
CO
NTR
O
L O
P
TIONS
Table 6.7.31 Remote Register in 4 X Mode (FRENIC-VG->Master)
Address Signal
name
Description
Remarks
RWrn+0
Monitored value 1 When RYnC is turned ON, the monitored value specified with
monitor code 1 is output.
RWrn+1
Monitored value 2 When RYnC is turned ON, the monitored value specified with
monitor code 2 is output.
RWrn+2
Response code
Response codes corresponding to RWwn+2 command code (refer
to Table 6.7.26) are set. For normal response, "0" is set. If data is
incorrect, the codes are set to a value other than "0".
RWrn+3
Read data
If the command code has normally been executed, the response
data for that command (specified by the command code) is
automatically written.
RWrn+4
Monitored value 3
RWrn+5
Monitored value 4
RWrn+6
Monitored value 5
RWrn+7
Monitored value 6
Outputs data of the monitor items specified with monitor codes 3
to 6 when RYnC is ON.
RWrn+8
Alarm code
The content of the alarm code specified in RWwn+8 is
automatically written into the lower 8 bits of RWrn+8. The upper
8 bits of RWwn+8 will be echoed back into the upper 8 bits of
RWrn+8.
For the alarm code, refer to
Chapter 4, Section 4.2.4.2,
Type [14].
RWrn+9 Motor
speed at the
time of latest
alarm
The motor speed with the alarm, specified with RWwn+8,
generated is stored. For alarms other than the latest one, response
is given with "0".
0 to ±20000
(Nmax with ±20000)
Supported only for the latest
alarm.
RWrn+A Output current at
the time of latest
alarm.
This register stores the output current applied at the occurrence
time of the alarm specified in RWwn+8. "0" is written except for
the latest alarm.
Rating of less than 75 kW:
Unit of 0.01 A
Rating of 75 kW or more:
Unit of 0.1 A
RWrn+B Output voltage at
the time of latest
alarm.
This register stores the output voltage applied at the occurrence
time of the alarm specified in RWwn+8. "0" is written except for
the latest alarm.
Unit of 0.1 V. "0" except for
the latest alarm.
RWrn+C Cumulative
power-ON time at
the latest alarm
occurrence
This register stores the cumulative power-ON time elapsed until
the occurrence time of the alarm specified in RWwn+8. "0" is
written except for the latest alarm.
Unit: 1 h
RWrn+D
|
RWrn+F
Not used.
-
n: Value determined by a station address
Содержание FRENIC-VG Series
Страница 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Страница 2: ......
Страница 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Страница 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Страница 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Страница 203: ...6 6 High Speed Serial Communication Capable Terminal Block 6 127 Chap 6 CONTROL OPTIONS Figure 6 6 3 ...
Страница 234: ...6 158 6 7 3 External dimension drawing 17 Unit mm Figure 6 7 5 Option PCB Outline Drawing Tightening torque 0 4 N m ...
Страница 344: ......
Страница 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...