6.6 High-Speed Serial Communication-Capable Terminal Block
6-149
Chap. 6
CO
NTR
O
L O
P
TIONS
Parameter code
Parameter name
M1 code
M2 code
M3 code
Coefficient of setting value in operation
with reduced number of inverters
Torque current
P09
A11
A111
x (1/No. of units participating in direct
parallel connection)
Slip frequency
(driving, braking)
P10, P11
A12, A13
A112, A113
Iron loss factor 1 to 3
P12 to P14
A14 to A16
A114 to A116
Magnetic saturation factor
1 to 5
P15 to P19
A17 to A21
A117 to A121
Secondary time constant
P20
A22
A122
Induced voltage factor
P21
A23
A123
R2 correction factor
1 to 3
P22 to P24
A24 to P26
A124 to A126
Exciting current correction
factor
P25 A27 A127
P-gain P26
A28
A128
ACR
Constant*2
I-time P27
A29
A129
Pulse resolution
P28
A30
A130
Thermistor selection
P30
A31
A131
1) Shaded parts in Table show the codes for which different setting values are set in M1 to M2
(M3) in the operation with reduced number of inverters.
Set the same setting values for other codes in M1 up to M2 (M3).
2) ACR constant *2 should be less than the standard set value when operating at direct parallel
connection. (Adjustment the constants while operating the motor.)
Use the reference setting values in the operation reduced to one unit of the inverter.
3) Use motor constants by assigning motor M2 selection and motor M3 selection [MCH2,
MCH3] of the X terminal function.
Table below indicates the setting values of motor constants in the cases of the direct parallel connection
system of two or three units of inverters and a single inverter, taking the motor constants of a 280 kW
motor as an example.
Table 6.6.21 Setting Example of Motor Constants
Setting value of function code
Remarks
Condition: No. of INVs
1 unit
2 units
3 units
No. of inverters connected to
one unit of motor
Drive control
P01
0
0
0
Motor selection
P02
37
37
37
Maximum speed
F03
1500
1500
1500
Rated speed
F04
750
750
750
Rated voltage
F05
380
380
380
Rated capacity
P03
280.00
140.00
93.33
x (1/No. of units participating in direct
parallel connection)
Rated current
P04
565.0
282.5
188.3
x (1/No. of units participating in direct
parallel connection)
Number of poles
P05
6
6
6
%R1 P06
1.12
1.12
1.12
%X P07
15.41
15.41
15.41
Содержание FRENIC-VG Series
Страница 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Страница 2: ......
Страница 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Страница 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Страница 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Страница 203: ...6 6 High Speed Serial Communication Capable Terminal Block 6 127 Chap 6 CONTROL OPTIONS Figure 6 6 3 ...
Страница 234: ...6 158 6 7 3 External dimension drawing 17 Unit mm Figure 6 7 5 Option PCB Outline Drawing Tightening torque 0 4 N m ...
Страница 344: ......
Страница 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...