![Fuji Electric FRENIC-VG Series Скачать руководство пользователя страница 300](http://html1.mh-extra.com/html/fuji-electric/frenic-vg-series/frenic-vg-series_user-manual_2341868300.webp)
6-224
6.11.5.3
Controlled variable input
(1) Speed
settings
When using DI input to set the speed, set function code F01 or C25 (whichever is to be enabled)
according to the switch state (DIA or DIB). For example, to enable F01 on a card set to DIA, set F01 to 6.
Control inputs [N2/N1] are used to switch between F01 and C25.
Table 6.11.8
When set to binary input
Set the maximum speed (F03) to 1,500 r/min.
To assign a speed setting of
600 r/min.
card.
DI
the
to
(B)
0100_0000
0001_1111_
Input
=
1F40(h)
8000(d)
1500
20000
600
=
=
×
To assign a speed setting of
-1000 r/min.
card.
DI
the
to
B)
1100_1011(
1100_1011_
Input
=
CBEB(h)
13333(d)
1500
20000
1000
=
−
=
×
−
BCD input is used in applications where the motor speed is converted to the machine speed. For example,
when a motor operating at 1,500 r/min. is connected to a machinery shaft via a 5:1 gear, the machinery
shaft will rotate at 300.0 r/min. DI input of 3,000 while using a BCD setting (o03 or o04) of 3,000 with
these function codes would result in rotation of 300.0 r/min. (1,500 r/min. for the motor).
Table 6.11.9
When set to BCD input
Set the maximum speed (F03) to 1,500 r/min.
Set the BCD input setting (o03 or o04) to 3,000.
(When the motor operates at 1,500 r/min., the machinery shaft will rotate
at 300.0 r/min.)
To set the machinery shaft to a
speed of 75.0 r/min.
(375 r/min. for the motor)
card.
DI
the
to
(B)
0101_0000
0000_0111_
Input
=
0750(BCD)
75.0
=
To set the machinery shaft to a
speed of -300.0 r/min.
(-1500 r/min. for the motor)
card.
DI
the
to
B)
0000_0000(
1011_0000_
Input
=
)3000(BCD)
(
300.0
−
=
−
(2) Torque, torque current, and torque limit input
When assigning DI input to torque (torque commands, torque current commands, and torque limits), it is
necessary to define DIA and DIB use with the function codes H41, H42, F42, and F43 according to the
function being used. For more information, see the corresponding sections of Chapter 4.
Table 6.11.10
When set to binary input
The torque scale uses the value 10,000 to represent 100%.
To assign 70% torque
card.
DI
the
to
B)
0101_1000(
0001_1011_
Input
=
1B58(h)
7000(d)
100
10000
70
=
=
×
To assign -25% torque
card.
DI
the
to
B)
0011_1100(
1111_0110_
Input
=
F63C(h)
2500(d)
100
10000
25
=
−
=
×
−
Содержание FRENIC-VG Series
Страница 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Страница 2: ......
Страница 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Страница 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Страница 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Страница 203: ...6 6 High Speed Serial Communication Capable Terminal Block 6 127 Chap 6 CONTROL OPTIONS Figure 6 6 3 ...
Страница 234: ...6 158 6 7 3 External dimension drawing 17 Unit mm Figure 6 7 5 Option PCB Outline Drawing Tightening torque 0 4 N m ...
Страница 344: ......
Страница 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...