![Fuji Electric FRENIC-VG Series Скачать руководство пользователя страница 297](http://html1.mh-extra.com/html/fuji-electric/frenic-vg-series/frenic-vg-series_user-manual_2341868297.webp)
6.11 DI Interface Card
6-221
Chap. 6
CO
NTR
O
L O
P
TIONS
6.11.4 Basic connection diagram
Refer to Section 6.1.4 "Installing internal options (OPC-VG1-
)" before performing wiring or
connection work.
• Performing connection work in an inappropriate manner may result in electric shock, fire, or other damage.
Qualified electricians should carry out wiring. When touching electrical circuits, for example when performing
connection work after the unit has been energized, shut off the power supply's circuit breaker to prevent
electric shock.
The smoothing capacitor remains charged even when the circuit breaker is shut off and will cause an electric
shock when touched. Verify that the inverter's charge lamp ("CHARGE") has turned off and use a tester or
other instrument to verify that the inverter's DC voltage has fallen to a safe level.
•
Do not use products with damaged or missing parts. Doing so may result in bodily injury or damage.
Inappropriate installation or removal of the product may cause damage to the product.
Table 6.11.4 Terminal Function Descriptions
Function Function
Pin No.
Name
BINARY BCD
Pin No.
Name
BINARY BCD
[1] CM
[11] CM
[2] DI0 2
0
= 1
1
×
10
0
= 1
[12]
DI8
2
8
= 256
1
×
10
2
= 100
[3] DI1 2
1
= 2
2
×
10
0
= 2
[13]
DI9
2
9
= 512
2
×
10
2
= 200
[4] DI2 2
2
= 4
4
×
10
0
= 4
[14]
DI10
2
10
= 1024
4
×
10
2
= 400
[5] DI3 2
3
= 8
8
×
10
0
= 8
[15]
DI11
2
11
= 2048
8
×
10
2
= 800
[6] CM
[16] CM
[7] DI4 2
4
= 16
1
×
10
1
= 10
[17]
DI12
2
12
= 4096
1
×
10
3
= 1000
[8] DI5 2
5
= 32
2
×
10
1
= 20
[18]
DI13
2
13
= 8192
2
×
10
3
= 2000
[9] DI6 2
6
= 64
4
×
10
1
= 40
[19]
DI14
2
14
= 16384
4
×
10
3
= 4000
[10] DI7 2
7
= 128
8
×
10
1
= 80
[20]
DI15
2
15
= 32768
Sign (ON: negative)
Figure 6.11.7
Note: As a rule, shielded wires are earthed.
However, if excessive induced noise from
external sources affects the system, the
effects of such noise can be reduced by
connecting shielded wires to 0 V.
Figure 6.11.8
19
20
1
3
2
4
5
7
6
8
9
11
10
12
13
15
14
16
17
18
Viewed from the plug’s soldered terminal
OPC-VG1-DI
MOTOR
FRENIC-VG
Main power supply
3-phase power
50/60 Hz
E
U
V
W
M
[TH1]
[THC]
NTC thermistor
U
V
W
L1/R
L2/S
L3/T
PG
[PGP]
[PGM]
[PA]
[PB]
SS,E
[P24]
[M24]
[P24]
[M24]
CN24
or
CN25
E
[19]
[18]
[17]
[16]
[20]
[14]
[13]
[12]
[11]
[15]
[9]
[8]
[7]
[6]
[10]
[4]
[3]
[2]
[1]
[5]
MSB
LSB
LSB
Bina
ry
inp
ut
BC
D
in
pu
t
Running
forward/
running
reverse
0V
0V
Содержание FRENIC-VG Series
Страница 1: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...
Страница 2: ......
Страница 3: ...High Performance Vector Control Inverter User s Manual Option Edition ...
Страница 155: ...6 5 SX Bus Interface Card 6 79 Chap 6 CONTROL OPTIONS Figure 6 5 5 ...
Страница 156: ...6 80 Basic Connection Diagram Figure 6 5 6 ...
Страница 203: ...6 6 High Speed Serial Communication Capable Terminal Block 6 127 Chap 6 CONTROL OPTIONS Figure 6 6 3 ...
Страница 234: ...6 158 6 7 3 External dimension drawing 17 Unit mm Figure 6 7 5 Option PCB Outline Drawing Tightening torque 0 4 N m ...
Страница 344: ......
Страница 346: ...For the STACK type User s Manual User s Manual Option Edition 24A7 E 0045 3 ...