INSTANT QUALITY REPORT SETTINGS AT END OF DATA RECORD
Settings for the protocol that is created when data recording is stopped.
The settings determine the parameters that are displayed in the quality
protocol. These settings do not affect the displays on the Home screen.
Individual Diagram for each channel
If you select this check-box, you will receive a separate diagram with the
respective strand tension for each channel. You can also record further
details of the channel.
“Low” — Indication of the lower threshold and highlighting of violations of
the lower thresholds.
“Up” — Display of the upper threshold highlighting of violations of the
upper threshold
The "Ref." - reference value is displayed as a line on the chart.
Single diagram for all channels
If you select this check-box, you will receive a diagram in which the strand
tensions of all channels are displayed together.
Threshold Violation Protocol
If you select this check-box, you will receive a table in which the threshold
violations of all channels are displayed in relation to the running meters.
5
Allow manual brake operation while recording data
if this checkbox is enabled – and if the logged-in user has the permission
– you will be able to toggle into "manual mode" during data recording.
-
Disable automatic control
-
Readjust reference value, thresholds are not affected
-
Manual operation for the brake actuator
-
Manual operation of all brake actuators "MASTER"
Refer to "Manual" Mode57
CAUTION
Manual operation of the brakes has immediate impact
on the strand tension and can lead to wire break!
You can disable the permission for this function in the user administration
menu.
Refer to User profiles and permissions p. 30
Table 16: Recipe manager