Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software
19.03.2019
45
Detail view channel
Pos. Description
10
Controls for tension monitoring and adjustment
Display of the reference value in the bar graph display as a black line
wire break
Display of the two parameters force and time interval. The wire break can
be used as a trigger function for relay outputs only when the icon is active.
Use alarm messages for relay outputs.
Only when alarm messages are activated, can relays also be switched by
threshold violations.
Threshold violations, violation of the pre-alarm, wire-break
delay time alarm messages
Once the conditions for an alarm are met, this time interval must elapse
until the relay is actually triggered.
Upper threshold
Display of the upper threshold as an orange line in the bar chart.
Activation of the upper threshold for the output as an alarm message.
If the upper pre-alarm is activated in the recipe, it is also displayed and
used as an alarm message for the output.
Lower threshold
Display of the lower threshold as an orange line in the bar chart. Activate
the lower threshold for the output as an alarm message.
If the lower pre-alarm is activated in the recipe, it is also displayed and
used as an alarm message for the output.
Display actual value in histogram
Enable automatic tension control
This channel is automatically controlled when data recording is started.