Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software
19.03.2019
52
Quality manager
Pos. Description
1
Search mask, filter
Here you can search for data records. Search criterion is the date on
which a recording was terminated.
2 PROCESS
DATA
RECORDINGS
This list contains all recorded datasets
The data of the individual columns are queried in a mask at the start of
the recording and can be entered pursuant to customer and product
requirements.
Recipe
Name of the applied recipe. The entry is performed automatically and
displays the loaded recipe at the start of the recording.
Data Record Note
These notes can be inserted during data recording, for example, to
document, special occurrences.
Production notes are only displayed here. They are not printed on quality
logs.
User name
First- and surname of the user who was logged in when the recording was
initiated.
3
SETTING FOR QUALITY REPORT HARDCOPY
You can create a quality log from any data recording. Here you define the
type and content of the quality log to be created.
Table 17: Quality manager
9.1
Quality protocols
You have the possibility to create quality protocols from past production runs.
Settings for creating a quality protocol
-
Select the appropriate settings.
-
The settings are the same as in the recipe manager, refer to Protocol Tension Force
Protocol per Channel p. 53ff.
-
Select one set from the list of data records by clicking on the corresponding row.
-
Press
-
The quality log is created in the background as a .pdf file and is automatically
displayed, as well as saved in the Downloads folder.
However, quality protocols always present the same structure.