Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software
19.03.2019
21
Seele/Core — tension of core strand (if installed)
Assign a unique name here for the force sensor.
RM – Production length, running meter (if installed)
Assign a unique name here for the force sensor.
Table 5: Basic setting — System settings — RTM Tension monitoring
6.4.4
MFD - Maximum Feedback Difference
The Maximum Feedback Difference is an automatically calculated value. The output
value can be described as a min-max range of actual values across all channels. It
always displays the difference between the largest and smallest actual values across all
channels.
The MFD thus illustrates, for example, a drifting of the actual values due to changing
braking forces on the cradles. The use of this value only makes sense if all channels
display the same reference value.
The MFD is displayed with a separate channel.
Figure 13: MFD, Maximum Actual Difference
A - The allowed bandwidth for the MFD at the set upper and lower thresholds.
B — current MFD at running metres, approx. 94m
C — current MFD at running metres, approx. 101m, threshold exceeded