Work steps and notes
Step
Observation
Reference braking force
Initially, set a lower value here to avoid wire breakage.
Start up the reference braking force immediately with
all brake actuators.
Table 21: Set up a new product
12.2
Setting up a new product
The following steps are for guidance:
-
Start recording — for example, enter “Setup” in the product name, which helps to
sort and find the correct data recording later.
-
Start-up the system
-
Enable manual operation
-
Adjust reference values
-
Manually adjust the brakes
-
Note down the braking forces at full coils
-
Adjust the reference braking force in the recipe
-
Stop system
-
Stop recording
-
Check product
Following the final product review (with approval), you can set the remaining
parameters:
-
Customize control parameters
o
Wider dead-band ± 10% (adjust to pre-alarm thresholds),
o
small correction angle 60°
o
longer delay time 20sec.
o
Note that fast regulation always results in reduced battery life.
-
Activate the pre-alarm
-
Set the pre-alarm thresholds on the dead-band of the control parameter, so that the
control unit is also triggered when the pre-alarm thresholds are reached.
-
Upper and lower thresholds with as narrow a range as possible to achieve high
product quality.
-
Enabling alarm output
-
Do not deactivate “Allow manual brake operation while recording data” until you are
satisfied with the product quality and no further manual intervention in automatic
control is necessary.
12.3
Production, data recording with automatic control
Note the following points:
-
All batteries have sufficient voltage for the production run
-
Correct recipe loaded
-
Enable data recording and enter product information correctly
-
Observe alarm messages