FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
59
of
170
[ 33-
DYNAMIC
]
WEIGHING OF UNSTABLE LOADS
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
[ 331
OPERATE
: NO
]
Operation type
Page 35
NO
KEY
SAUT
:
:
:
Disable
Dynamic weighing starts after repressing the
key if W >50e.
Dynamic weighing starts automatically if W >50e.
CONT
MINW
CMIN
:
:
:
Continuous dynamic weighing.
Dynamic weighing starts if W > Min Weight.
Continuous dynamic weighing starts if W > Min
Weight.
[ 332
FILTER
: 3.0
]
Dynamic filtering time.
X.X seconds.
[ 34-
KEY LOCK
]
KEY LOCK
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
[ 341
UP KEY
: USE
]
Setpoint key locking
USE
LOCK
:
:
Not locked
Locked
[ 342
DOWN
: USE
]
Memory key locking
USE
LOCK
:
:
Not locked
Locked
[ 343
ENTER
: USE
]
Enter key locking
USE
LOCK
:
:
Not locked
Locked
[ 344
* KEY
: USE
]
* key locking
USE
LOCK
:
:
Not locked
Locked
[ 345
ID
: USE
]
ID1 and ID2 keys locking
USE
LOCK
:
:
Not locked
Locked
[ 346
M+ MRC
: USE
]
M+ key locking
USE
LOCK
:
:
Not locked
Locked
[ 347
TARE
: USE
]
Tare key locking
USE
LOCK
:
:
Not locked
Locked
[ 348
ZEROING
: USE
]
Zeroing key locking
USE
LOCK
:
:
Not locked
Locked
[ 349
Δ KEY
: USE
]
Δ key locking
USE
LOCK
:
:
Not locked
Locked