FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
141
of
170
Figure 14.8
– Station information
Input/Output
Definition
Description
Remote Register ( RWr )
RWr0, RWr1
1
st
Dword Input (
FT-112(D) Panel Output to PLC Input
)
RWr2, RWr3
2
nd
Dword Input (
FT-112(D) Panel Output to PLC Inpu
)
Remote Input ( RX )
RX0 ~ RX31
Not used
Remote Register ( RWw )
RWw0, RWw1
1
st
Dword Output (
PLC Output to FT-112(D) Panel Input
)
RWw2, RWw3
2
nd
Dword Output (
PLC Output to FT-112(D) Panel Input
)
Remote Output ( RY )
RY0 ~ RY31
Not used
14.6.3 CC-Link Data Structure
For the Data Structure for CC-Link see Appendix 1,
page 146