FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
55
of
170
[ 222
DATA
: TARE
] Information data on the left of the alphanumeric display.
NO
TARE
GROS
ID1
ID2
TOTA
Q+TO
GTOT
:
:
:
:
:
:
:
:
No data
Tare weight is displayed
Gross weight is displayed in Net
ID1 Data
ID2 Data
Total
Quantity and total
Grand Total
Note: The par 221 is set to NO, if this parameter isn't programmed
NO, TARE or GROS.
[ 23-
START UP
]
START UP
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
[ 231
TARING
: MULT ] Taring.
Page 34
NO
MULT
GROS
PT
PT-G
:
:
:
:
:
Disabled.
Tare with key, via serial interface or via digital input.
Tare with key, via serial interface or via digital input
only at gross.
Preset tare and tare with key or via serial interface.
Preset tare and tare with key or via serial interface at
gross.
[ 232
AUTO T
: NO
] Auto taring.
Page 34
NO
YES
:
:
Disabled.
Auto tare, if the gross load is bigger than MIN TARE
and stable.
[ 233
AUTO
CLR
: NO
] Auto clear.
Page 34
NO
YES
:
:
Disabled.
Auto clear, if the gross load is lower than 10d.
[ 234
PWR
TARE
: NO
] Restore Tare at power on
NO
YES
:
:
Disabled.
Tare value is saved at power off and the indication is
start in NET after switch on the instrument.
[ 235
FILTER
: MEDI
] Adaptive digital filter.
NO
VLO
W
LOW
MEDI
HIGH
VHIG
:
:
:
:
:
:
Disable. Fastest weighing; but the most sensitive to
environmental vibrations.
Very low filtering
Low filter
Medium filter
High filter
Very high filter. Slowest and the most stable weighing.
[ 236
LANGUAGE
: ENG
] User language.
ENG
DEU
FRA
ITA
ESP
TUR
:
:
:
:
:
:
English
Deutsch
Français
İtaliano
Espagnol
Türkçe
[ 237
NET SIGN : NO
] Net sign correction at displaying and printing.
NO
YES
:
:
Disabled.
Enabled.