FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
122
of
170
40077
R
2
6
th
Peak value
40079
R
2
7
th
Peak value
40081
R
2
8
th
Peak value
40083
R
2
9
th
Peak value
40085
R
2
10
th
Peak value
40127
R/W 2
Dynamic filter
Refer to parameter [332], page 59
40129
R/W 2
Digital filter
Dec
Description
0
No
1
Very Low
2
Low
3
Medium
4
High
5
Very High
40131
R/W 2
Power on zero
0
Disable
1
± 2%
2
± 2%LK
3
± %10
4
+ %15, - %5
5
± %20
40133
R/W 2
Zeroing Range
0
Disable
1
± 2%
2
± 3%
3
± 20%
4
± 50%
40135
R/W 2
Auto Zero Tracking
0
Disable
1
± 0,3d
2
± 0,5d
3
± 1d
4
± 2d
5
± 3d
40137
R/W 2
Tare
0
No
1
Multi tare
2
Tare only at gross
3
Preset tare
4
Preset tare at gross
40139
R/W 2
Stability
Detection Range
0
± 0,3d
1
± 0,5d
2
± 1d
3
± 2d
4
± 3d
5
± 4d
6
Disable
40141
R/W 2
Stability Time
Refer to parameter [517] on page 64
40143
R/W 10
Reserve
40153
R/W 2
Unit
Dec
Description
0
g
(Gram)
1
kg
(Kilogram)
2
t
(Ton)
3
lb
(Libre)
4
No unit
(without unit)
5
N
(Newton)
6
kN
(Kilonewton)
7
kLb
(Kilolibre)
40155
R/W 2
Range
0
Single range
1
2 x MR
2
3 x MR
3
2 x MI
4
3 x MI
40157
R/W 2
MAX-1
Refer to parameter [523] on page 65