S NET Free setpoint of net weight
The digital output is activated with comparing the set point value and net weight value as shown below.
Example:
if SP1
SP1
LOW
SP1
HIGH
SP2
SP2
LOW
SP2
HIGH
= 100 kg or
= 100 kg
= 150 kg
= -200kg or
= -200kg
= -225kg
BAS-HI
Basic, active high
Output is high if net weight is heavier
than setpoint.
(Default)
BAS-LO
Basic, active low
Output is low if net weight is heavier
than setpoint.
THR-HI
Threshold, active high
Output goes to high if net weight is
heavier than setpoint high. Returns the
low if the weight is less than setpoint
low.