FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
140
of
170
CC-Link
After setting related parameters you can communicate with FT-112(D) Panel via CC-Link network. Supported
CC-Link version is v1.10 and baud rates are 156 kbps (default), 625 kbps, 2,5 Mbps, 5 Mbps and 10 Mbps.
There are 2 LED’s near the CC-Link connector which are;
(A) Run LED
State
Indication
Off
No network participation, timeout status (no power)
Green
Participating, normal operation
Red
Major fault (FATAL error)
(B) Error LED
State
Indication
Off
No error detected (no power)
Red
Major fault (Exception or FATAL event)
Red, flickering
CRC error (temporary flickering)
Red, flashing
Station Number or Baud rate has changed since startup (flashing)
In the case of red LED warning, check cabling, configuration and station number. Power off the instrument and
reenergize the instrument 30 seconds later.
14.6.1 Data Format
Data format of weight value can be programmable for Floating point (IEEE 754) or Integer. Refer to parameter
[ 191 ].
14.6.2 CC-Link Configuration
The weighing indicator has occupied one station area on CC-Link network and station type of weighing
indicator mu
st be programmed as ‘Remote device station’ in the PLC software. CC-Link configuration for PLC
programmers is shown in Figure 14.8.
1
(A) RUN LED
2
(B) ERR LED
3
CC-Link interface