FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
162
of
170
2
± %2LK
3
± %10
4
+ %15, - %5
5
± %20
01000010
66
R/
W
Zeroing Range
(1)
(2)
0
Disable
1
± 2%
2
± 3%
3
± 20%
4
± 50%
01000011
67
R/
W
Auto Zero
Tracking
(1) (2)
0
Disable
1
± 0,3d
2
± 0,5d
3
± 1d
4
± 2d
5
± 3d
01000100
68
R/
W
Tare
(1) (2)
0
No
1
Multi tare
2
Tare only at gross
3
Preset tare
4
Preset tare at gross
01000101
69
R/
W
Stability
Detection
Range
(1) (2)
0
± 0,3d
1
± 0,5d
2
± 1d
3
± 2d
4
± 3d
5
± 4d
6
Disable
01000110
70
R/
W
Stability Time
(1) (2)
Refer to par. [517] page 64
01000111
71
R/
W
Unit
(1) (2)
0
g
1
kg
2
t
3
lb
4
No unit
5
N
6
kN
7
kLb
01001000
72
R/
W
Range
(1) (2)
0
Single range
1
2 x Multi Range
2
3 x Multi Range
3
2 x Multi Interval
4
3 x Multi Interval
01001001
73
R/
W
Capacity-1
(1) (2)
Refer to par. 523 on page 65
01001010
74
R/
W
Decimal
point-1
(1) (2)
0
XXXXOO
1
XXXXXO
2
XXXXXX
3
XXXXX.X
4
XXXX.XX
5
XXX.XXX
01001011
75
R/
W
Increment-1
(1) (2)
0
X1
1
X2
2
X5
01001100
76
R/
W
Capacity-2
(1) (2)
01001101
77
R/
W
Decimalpoint-2
(1)
(2)
01001110
78
R/
W
Increment-2
(1) (2)
01001111
79
R/
W
Capacity-3
(1) (2)