background image

GENERAL DESCRIPTION

The CTVUE-315C Operator Interface combines powerful features normally

found only in PC-based HMIs, with the reliability of a dedicated operating
system. It is built around a high performance core with integrated features,
allowing it to provide SCADA-like functionality at a fraction of the cost.

The 315 is able to act as a multiple protocol converter using four high-speed

RS232/422/485 communications ports and an Ethernet 10/100 Base-TX port.
The Ethernet port supports up to four protocols simultaneously, allowing
dissimilar Ethernet based products to communicate with one another.

The 315's USB port allows fast downloads of configuration files and access

to trending and data logging. A CompactFlash socket is provided so that
standard ComplactFlash cards can be used to collect your trending and data
logging information as well as to store configuration files. The built-in web
server allows processes to be controlled remotely.

The 315's large, high-resolution display allows users to easily view and enter

information. Data can be manipulated through the touchscreen and/or the 10-
button keypad.

ORDERING INFORMATION

CONTENTS OF PACKAGE

- 315C Operator Interface.
- Panel gasket.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.

CompactFlash is a registered trademark of CompactFlash Association.

O

CONFIGURED USING CTVue CONFIGURATOR SOFTWARE 

O

UP TO 6 RS-232/422/485 COMMUNICATIONS PORTS 
(2 RS-232 AND 2 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS422/485 ON OPTIONAL COMMUNICATIONS CARD)

O

10 BASE T/100 BASE-TX ETHERNET PORT SUPPORTS
MULTIPLE PROTOCOLS SIMULTANEOUSLY

O

BUILT-IN WEB SERVER AND FTP SERVER/CLIENT

O

USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM
A PC OR FOR DATA TRANSFERS TO A PC

O

UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE
MEMORY (32 MBYTE FLASH)

O

COMPACTFLASH

®

SOCKET FOR DATABASE/RECIPE STORAGE

AND DATA LOGGING

O

15-INCH TFT ACTIVE MATRIX 32K COLOR XGA 1024 X 768
PIXEL LCD

O

10-BUTTON KEYPAD FOR ON-SCREEN MENUS

O

THREE FRONT PANEL LED INDICATORS

O

POWERED BY 24 VDC ±20% SUPPLY

O

RESISTIVE ANALOG TOUCHSCREEN

CAUTION: Risk Of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

DESCRIPTION

PART NUMBER

Operator Interface for indoor applications, textured finish
with embossed keys 

CTVUE-315C

CTVUE-DN00

CTVUE-CN00

CTVUE-PBDP

CTVUE-RS00

CTVue Configurator 2.0

RS-232 Programming Cable

CTVUE-PROG

USB Cable

CTVUE-USB

The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.

CANopen Optional Communication Card

MODEL 315C - GRAPHIC COLOR LCD OPERATOR INTERFACE TERMINAL

WITH TFT XGA DISPLAY AND TOUCHSCREEN

Profibus DP Optional Communication Card

1

RS232/485 Optional Communication Card

Bulletin No.  CTVUE-315C-X
Drawing No.  LP0760
Released  7/08

Tel +1 952 995 8000 
Fax +1 952 995 8099
www.emersonct.com

DeviceNet option card for G3 operator interfaces with
isolated high speed communications ports 

CTVUE-CONFIG-CD

400370-08, Rev: X

Содержание DRIVE CENTRE 315C

Страница 1: ...her actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller CompactFlash is a registered trademark of CompactFlash...

Страница 2: ...ernet network to CTVue operator interface 1500 Vrms 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 20 to 70 C Operating and Storage Humidity 80 maximum rela...

Страница 3: ...ts of power Items that could cause increases in current are additional communications optional communications card CompactFlash card and other features programmed through CTVue Configurator In any cas...

Страница 4: ...er This driver is installed with CTVue Configurator and is located in the folder C Program Files Control Techniques CTVUE Device after CTVue Configurator is installed This may have already been accomp...

Страница 5: ...an be used for either master or slave protocols DH485 Connections The 315 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to co...

Страница 6: ...fault status of the LEDs 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the...

Страница 7: ...TIONAL FEATURES AND ACCESSORIES COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards Use cards with a minimum of 4Mbytes with the 315 s CompactFlash so...

Страница 8: ......

Отзывы: