FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
147
of
170
B5 … B1
Read
Command
Response
Bin
Dec
Descriptions
00000
0
Actual weight (if the indication is in Net)
00001
1
Gross weight
00010
2
Tare weight
00011
3
ALL Status ( Refer to Table 15-1
)
00100
4
Calibration Status ( Refer to Table 15-2
)
00101
5
Last print value
00110
6
Quantity of M+
00111
01010
7
10
Not used
01011
11
CN (Label number)
01100
12
Totalization of M+
01101
13
Grand Total
01110
14
Not used
01111
15
B. weighing
Filling
C.weighing
Classifyin
g
Peak hold
SetPoint-1 Target
Target
Target
Follow
10000
16
SetPoint-2 Coarse
Low
--Low
Mid Decr.
10001
17
SetPoint-3 Fine
High
-Low
End Decr.
10010
18
SetPoint-4 TareMin
Empty
+High
Stop
10011
19
SetPoint-5 Tar
eMax
Not used
++High
Alarm
10100
20
Not used
Empty
Not used
Empty
Empty
10101
21
SetPoint-1 Low
Only available for Threshold and
Window feature.
Refer to sub-block 36-,
to see the availabilities.
10110
22
SetPoint-2 Low
10111
23
SetPoint-3 Low
11000
24
SetPoint-4 Low
11001
25
SetPoint-5 Low
11010
11110
26
30
Not used
11111
31
Expanded Commands List
(Refer to Table 15-3)
B0
CMD Flag
Toggles
The command is applied successfully
ALL Status (always 32 bit integer)
1
st
Dword (input) descriptions when read command is ‘ALL Status’. Refer to 2
nd
Dword of PLC Output to FT-
112(D) Panel Input.
Bit Number
1
st
Dword (input) Description
B31
Place of decimal point
0
None
1
No decimal point
B30
0
None
1
Decimal point is X.X
B29
0
None
1
Decimal point is X.XX
B28
0
None
1
Decimal point is X.XXX
B27
0
None
1
Decimal point is X.XXXX
B26 … B16
Not in use
B15
Hold status
0
Passive
1
Active
B14
Basic Peak status
0
Passive
1
Active
B13
High resolution status
0
Passive
1
Active
B12
Centre of zero
0
Weight is out of zero range
1
Weight is in zero range
B11
Key lock status
0
Passive
1
Active
B7-B10
Not used