FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
159
of
170
PLC Output to FT-112(D) Panel Input
Bitwise of a Dword:
Unsigned
Long
(R/W)
B63 B62 B61 B60 B59 B58 B57 B56 B55 B54 B53 B52 B51 B50 B49 B48
B47 B46 B45 B44 B43 B42 B41 B40 B39 B38 B37 B36 B35 B34 B33 B32
B31 B30 B29 B28 B27 B26 B25 B24 B23 B22 B21 B20 B19 B18 B17 B16
B15 B14 B13 B12 B11 B10 B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
RxPDO 1
(R_UL1)
Out
5
Out
4
Out
3
Out
2
Out
1
Expanded Commands List
Not in use
Command List
Read Data Selection
New
CMD
B37-B33 bits defines the usage of this Dword.
PLC Output to FT-112(D) Panel Input RxPDO 1 (R_UL1)
Bit
Number
RxPDO 1 (R_UL1) descriptions
B63 …
B56
Set / Reset digital outputs
B55 …
B48
Expanded Commands List (Refer to Table 16-3)
B47 …
B43
Not in use
B42 …
B38
Command
List
Bin
Dec Commands
00000 0
None command is activated
00001 1
Zero
00010 2
Tare
00011 3
Clear
00100 4
00101 5
Adjust zero calibration
Calibration
00110 6
Adjust span calibration
(1)
00111 7
Total Load Cell Capacity
(1)
eCal
Coefficients
Refer to par. [613]
01000 8
Average mV/V value
(1)
01001 9
Dead Load value
(1)
01010 10
Save the coefficients of eCal
01011 11
CN (Label number)
(1)
01100 12
Preset Tare
(1)
01101 13
Grand Total
01110 14
Not used
01111 15
B. weighing
Filling
C.weighing
Classifying
Peak hold
Set Point-
1
Target
Target
Target
Follow
10000 16
Set Point-
2
Coarse
Low
--Low
Mid
Decr.
10001 17
Set Point-
3
Fine
High
-Low
End
Decr.
10010 18
Set Point-
4
TareMin
Empty
+High
Stop
10011 19
Set Point-
5
TareMax Not used
++High
Alarm