D.7.2 Installation of the remote control panel
The control cables are securely connected
to the genset. On the back of the control
panel is a terminal block for the remote
control cable.
Please ensure that the remote control
panel is installed in a protected, dry and
easily accessible place.
Fig. D.29: Remote control panel - back side
D.7.3 The speed sensor
Speed sensor
Fig. D.30: Speed sensor
Installation of the speed sensor
The speed sensor tip must have between 0.3 to 0.8mm of clearance (air gap) from the gear tooth
tips. In order to achieve this clearance: the speed sensor tip should be aligned with the tip of a
gear tooth and screwed in until it touches the tip of the tooth. (
ATTENTION! Ensure that when
inserting the sensor, that the sensor tip is not screwed into the root of the gear tooth)
. The
screw is subsequently turned anticlockwise by half a turn (0.3 to 0.8mm) and held by a counter